OPERATION
119
6.
Go to the
ON Phs
setting and set the starting
phase of the step. Not applicable for Trans1 or
Trans2.
ON Phase
ON, OFF
ON Phase
0~ 359º
Resolution
1º
7.
Go to the
OFF Phs
setting and set the end
phase of the step. Not applicable for Trans1 or
Trans2.
OFF Phase
ON, OFF
OFF Phase
0~ 359º
Resolution
1º
8.
Press the
Range
key repeatedly to set the
voltage range for the Vset parameter. The
range will be shown in the top corner, which
indicates that the simulation will be executed
within this voltage range.
Range
Range
LO(155V), MD(310V), HI(600V,
optional)
9.
Go to the
Vset
setting and set the Vrms level of
the step. If you input a Vset value that is not
within the voltage range, the input value will
be ignored.
Not applicable for Trans1 and Trans2.
Vset
0.00 ~ 310.0Vrms (range dependent)
(600V optional)
Содержание APS-7000 Series
Страница 1: ...Programmable AC Power Source APS 7000 Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Страница 25: ...GETTING STARTED 25 Indicates that the panel lock is active ARB Indicates that the ARB function is active ...
Страница 89: ...OPERATION 89 Exit 4 Press Exit F4 to exit from the MISC Configuration settings Example Settings ...
Страница 111: ...OPERATION 111 Simulate Example ...
Страница 157: ...COMMUNICATION INTERFACE 157 Exit 6 Press Exit F4 to exit from the serial port settings ...
Страница 187: ...APPENDIX 187 APS 7000 Dimensions APS 7050 402 545 5 430 110 4 87 9 Scale mm ...
Страница 188: ...APS 7000 Series User Manual 188 APS 7100 561 6 705 5 430 110 4 87 9 Scale mm ...
Страница 189: ...APPENDIX 189 APS 7200 402 5 310 5 429 8 682 4 649 2 Scale mm ...
Страница 190: ...APS 7000 Series User Manual 190 APS 7300 491 5 399 5 429 8 682 4 649 2 Scale mm ...