Note
The RS-232/USB (APS-002) or RS-232 (APS-007)
must first be installed before the RS-232 interface
can be used for remote control. Please see page 41
for installation details.
Steps
1.
Connect the RS-232C cable from
the PC to the rear panel RS-232
port.
2.
Press the
Menu
key. The Menu
setting will appear on the display.
Menu
3.
Use the scroll wheel to go to item 7,
Serial Port
and press
Enter
.
4.
Go to the
Function Active
setting and turn the
serial port connection on.
Function Active
ON, OFF
5.
Set the remaining serial port settings.
Baud rate
1200, 2400, 4800,
9600(default), 19200, 38400,
57600, 115200,
Data bits
7, 8(default)
Parity
None(default), odd, even
Stop bits
1(default),2
Serial port configuration
Содержание APS-7000 Series
Страница 1: ...Programmable AC Power Source APS 7000 Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Страница 25: ...GETTING STARTED 25 Indicates that the panel lock is active ARB Indicates that the ARB function is active ...
Страница 89: ...OPERATION 89 Exit 4 Press Exit F4 to exit from the MISC Configuration settings Example Settings ...
Страница 111: ...OPERATION 111 Simulate Example ...
Страница 157: ...COMMUNICATION INTERFACE 157 Exit 6 Press Exit F4 to exit from the serial port settings ...
Страница 187: ...APPENDIX 187 APS 7000 Dimensions APS 7050 402 545 5 430 110 4 87 9 Scale mm ...
Страница 188: ...APS 7000 Series User Manual 188 APS 7100 561 6 705 5 430 110 4 87 9 Scale mm ...
Страница 189: ...APPENDIX 189 APS 7200 402 5 310 5 429 8 682 4 649 2 Scale mm ...
Страница 190: ...APS 7000 Series User Manual 190 APS 7300 491 5 399 5 429 8 682 4 649 2 Scale mm ...