32
EN
Inspection and maintenance plan
Repairs and works specified in these Instructions may only be performed by qualified authorised staff. Use only original
accessories and original spare parts.
Regular servicing period
Before any
start-up
Monatlich
Alle 3 Monate,
oder jeweils
nach 50 Be-
triebsstunden
After 6 months
Engine oil
(
5W30 / 10W30
)
Inspection
Change
Petrol hose
Exhaust system
Choke
Cable starter
Inspection
Air filter
Clean
Change
Spark plug
Inspection
Clean
Tip:
To ensure reliable operation of the electric generator, we strongly recommend using fuel additives and performing
2-3 test operations after a longer time of not using the unit.
Failure removal
Failures
Causes
Removal
The motor does not start
Lack of fuel
Add some fuel
Bad fuel,Storage without first emptying
the petrol tank
Drain the fuel tank and carburettor. Add
fresh petrol.
Little oil in the engine
Add oil
Unit is not in a horizontal position. Lack
of oil being signalled
Place the device horizontally.
Engine running irregularly
Air in the fuel line
Vent generators
Wrong fuel (propellant)
Make sure proper fuel has been used.
Unit not producing any
current.
Short circuit
Broken cable
Loose cable
An error that you can remove yourself.
Contact the GÜDE service centre.
Engine stopping.
The Starting current is too big.
Reduce the appliance
Too long cable
Shorten the cable
ENGLISH
Содержание 40721
Страница 8: ...4 6 7 MAX MAX MIN MIN 4 2 1 3 5W30 10W30 5 0 6L ...
Страница 10: ...6 3 RUN STOP OFF RUN STOP OFF MAX 7 8 L 2 1 SUPER PLUS SUPER BENZIN E10 ...
Страница 15: ...11 RUN STOP OFF RUN STOP OFF 2 1 2 3 5 4 6 S TA R T 2 3 min ...
Страница 16: ...12 RUN STOP OFF RUN STOP OFF 3 4 2 1 S T O P ...
Страница 20: ...16 1 2 3 ...
Страница 21: ...17 7 6 0 6 0 8 mm 5 4 TOOL BAG 2 1 ...
Страница 22: ...18 2 4 3 5 8 MAX MIN 6 7 1 5W30 10W30 0 6L ...
Страница 23: ...19 2 1 3 4 H2 O ...
Страница 24: ...20 ADDITIV 1 START STOP 10 min 2 2 3 x START STOP year 3 ...