87
©2016 Guangzhou ZHIYUAN Electronics
Date: 2016/12/08
User Manual
V1.00
C
Guangzhou ZHIYUAN Electronics Co., Ltd.
PA5000 Series Power Analyzer Start Guide
50A element 2A range: I
rms
is in the allowable range of 1~110%; the current and
power accuracy is added 2A×reading (A)
-1
× 0.002% of the range.
External sensor 50mA range: input voltage RMS value is in the allowable range
of 1~110%; the current and power accuracy is added 50mV×input voltage (mV)
-1
× 0.025% of the range.
8.3.2
Input Range
The input signal amplitude should be within the allowed measurement range.
Udc and Idc should be 0
〜
±110% of the measurement range.
Urms and Irms should be 1
〜
110% of the measurement range.
Umn and Imn should be 10
〜
110% of the measurement range.
Urmn and lrmn should be 10
〜
110% of the measurement range.
The synchronous source level should satisfy the input signal level for frequency
measurement.
8.3.3
Input Display Value
The maximum display value is 140% of the voltage or current rated range.
The minimum display value Urms, Uac, Irms and Iac can be as low as 0.5% of the
measurement range.
Umn, Urmn, Imn and Irmn can be as low as 1% of the measurement range.
8.3.4
Influence of Line Filter
When the cut-off frequency (fc) is 100Hz~100kHz
Voltage/current
0.1Hz ~ fc/2: [(f/fc)
4.2
× 60% + (f/1000kHz)
2
× 60%] of the reading
DC: 0.05% of the range
Power
0.1Hz ~ fc/2: [(f/fc)
4.2
× 120% + (f/1000kHz)
2
× 120%] of the reading
DC: 0.1% of the range
When the cut-off frequency (fc) is 300kHz
Voltage/current
0.1Hz ~ fc/10: (f/300kHz)
2
× 60% of the reading
DC: 0.1% of range
Power
0.1Hz ~ fc/10: (f/300kHz)
2
× 120% of the reading
DC: 0.2% of the range