Appendix 5. Parameters
315
Appendi
x
0
~
±99999999 unit: 0.0001inch (inch output)
0
~
±99999999 unit: 0.001° (rotary axis)
1 6 3
1 6 4
1 6 5
1 6 6
4 3 6
PECINTX, PECINTY, PECINTZ, PECINT4, PECINT5 respectively set the pitch error
compensation intervals.
Setting value: 8000
~
20000000 unit: 0.001mm (metric output)
4000
~
20000000 unit: 0.0001inch (inch output)
6000 unit: 0.001 deg (rotary axis)
Note 1: When the setting value is 0, the compensation is not performed.
Note 2: If the 4th axis is rotary axis, the parameter must be set to 6000.
1 6 7
ATCLZV sets the stroke limit on Z axis negative direction.
Setting value: 0
~
±99999999 unit: 0.001mm (metric output)
0
~
±99999999 unit: 0.0001inch (inch output)
1 6 8
MASKA sets a password for programs numbered 9000
~
9899.
Setting value: 1
~
99999999
Note: When the parameter No.168 is 0, the programs are in unlocked mode and they are not affected by
the power ON/OFF. Note that when the programs should be unlocked, the parameter must be 0.
1 7 1
1 7 2
1 7 3
1 7 4
1 7 5
1 7 6
1 7 7
1 7 8
1 7 9
FIDF1
~
9 respectively set the feedrates of F1-digit commands F1
~
F9 .
Setting value: 0
~
15000 unit: 0.1mm/min (metric output)
0
~
6000 unit: 0.01inch/min (inch output)
The feedrates can also be set in “SETTING” screen.
PECINTX
PECINTY
PECINTZ
PECINT4
PECINT5
ATCLZV
Password
FIDF1
FIDF2
FIDF3
FIDF4
FIDF5
FIDF6
FIDF7
FIDF8
FIDF9
Содержание GSK983Ma
Страница 124: ......
Страница 130: ...GSK983Ma Milling Machine Center CNC System User Manual 118 Part 1 Programming Rapid traverse Cutting feed ...
Страница 133: ...Chapter Three Programming 121 Part 1 Programming Rapid traverse Cutting feed 6 G82 Drilling cycle boring ...
Страница 143: ......
Страница 185: ......
Страница 209: ...Chapter Four Operation 197 Part 2 Operation ...
Страница 239: ...Chapter Four Operation 227 Part 2 Operation ...
Страница 242: ......
Страница 279: ......
Страница 296: ...GSK983Ma Milling Machine Center CNC System User Manual 284 Part 2 Operation ...
Страница 297: ...Appendix 285 APPENDIX Appendix 1 System Version Display The system version is displayed immediately after power on ...
Страница 371: ...Appendix 11 USB Interface Parameter Transfer Operation ...