Appendix 5. Parameters
303
Appendi
x
0 3 9
0 4 0
0 4 1
0 4 2
4 1 6
PECZRX
~
5 set the pitch error origin point for X, Y, Z, 4th, 5th axes respectively.
Setting value: 0
~
127
Setting some points corresponding to reference point (machine zero point), for example, the
pitch error origin point is set to 0, the setting point 1 is in position
+
8.000mm, thus compensation
range of the setting point 127 in position 1016.000mm is 0 mm
~
1016.000mm.
When the pitch error compensation interval (parameter 163~166) is 8000.
0 4 3
0 4 4
0 4 5
0 4 6
0 4 7
0 4 8
0 4 9
0 5 0
0 5 1
0 5 2
UMMCD4
~
UMMCD13
The number of M codes that call macro programs can be set up to 10 (can be the assignment
value of argument)
Setting value: 01
~
97
0 5 3
MACINTON: Custom macro interrupts valid M code
Setting value: 03
~
97
This parameter is valid when the parameter No.25 bit 4 MPRM=1.
PECZRX
PECZRY
PECZRZ
PECZR4
PECZR5
UMMCD4 The M code that calls macro program O9020
UMMCD5 The M code that calls macro program O9021
UMMCD6 The M code that calls macro program O9022
UMMCD7 The M code that calls macro program O9023
UMMCD8 The M code that calls macro program O9024
UMMCD9 The M code that calls macro program O9025
UMMCD10 The M code that calls macro program O9026
UMMCD11 The M code that calls macro program O9027
UMMCD12 The M code that calls macro program O9028
UMMCD13 The M code that calls macro program O9029
MACINTON
Содержание GSK983Ma
Страница 124: ......
Страница 130: ...GSK983Ma Milling Machine Center CNC System User Manual 118 Part 1 Programming Rapid traverse Cutting feed ...
Страница 133: ...Chapter Three Programming 121 Part 1 Programming Rapid traverse Cutting feed 6 G82 Drilling cycle boring ...
Страница 143: ......
Страница 185: ......
Страница 209: ...Chapter Four Operation 197 Part 2 Operation ...
Страница 239: ...Chapter Four Operation 227 Part 2 Operation ...
Страница 242: ......
Страница 279: ......
Страница 296: ...GSK983Ma Milling Machine Center CNC System User Manual 284 Part 2 Operation ...
Страница 297: ...Appendix 285 APPENDIX Appendix 1 System Version Display The system version is displayed immediately after power on ...
Страница 371: ...Appendix 11 USB Interface Parameter Transfer Operation ...