Inline Centrifugal Fan Pad Guidelines
If a fan is to be installed, refer below image to determine the concrete pad size.
• The top of this pad must be level with the top of the bin’s foundation.
• Recommended pad thickness is 4 in. minimum.
• Front of pad must be perpendicular to bin wall.
• Pad for heater not required.
CAUTION
Fan pad and fan must be leveled and smooth for proper operation. Vibration
problems can result from improper fan leveling.
Figure 3-5
Centrifugal fan foundation
A
22 in. for TR-4734
48 in. for TR-7048
C
Bin center
B
Fan foundation
D
Bin wall
32
PNEG-4936
36 Ft. TopDry Autoflow