![GSi 40-SERIES Скачать руководство пользователя страница 93](http://html1.mh-extra.com/html/gsi/40-series/40-series_construction-manual_2275090093.webp)
5. Bend the eave angle tabs (G) upward to conform with each roof panel rib.
6. Install the optional tab seal (F) to the tabs (G) of the eave angle (A) as shown from the inside of the
bin.
7. Tighten all hardware to the recommended torque specification. See
.
Figure 8-4
Exploded view of eave angle
A
First eave angle (CTR-0721)
E
5/16 in. flange nut (S-3611)
B
One-ring top stiffener
F
Second eave angle (CTR-0721)
C
Eave angle tab
G
Optional tab seal (CRP-4802)
D
5/16 x 1 in. flange bolt with sealing
washer (S-10260)
H
Top sidewall sheet
After You Finish
Continue this procedure for the remaining eave angles.
PNEG-4472
72 Ft Diameter Z-Tek Bins
93
Содержание 40-SERIES