![GSi 40-SERIES Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/gsi/40-series/40-series_construction-manual_2275090050.webp)
Stiffener Splice Location
1. All stiffeners should be installed on the exterior of the bin.
2. Attach the stiffener splice (C or D) to splice the two stiffeners (A and B) 10 in. above the horizontal
seam (E) of the bin sidewall.
3. Use 3/8 in. x 1 in. bin bolt to install the splice to the stiffeners.
NOTE:
Make sure to have the bolt head on the inside of the bin.
Figure 6-2
Stiffener splice location
A
Top stiffener
D
Long splice
B
Bottom stiffener
E
Horizontal seam in bin sidewall
C
Short splice