Installing the Roof Flashing
The roof flashing will seal the area between the center collar and the roof panels.
What You Should Know
Each roof flashing section overlaps and bolts together with the previously installed roof flashing section.
1. Install the first roof flashing section (A) onto the roof panel, and align the holes on the roof flashing
with the roof panel.
NOTE:
Flashing is not supposed to be attached to the center collar.
2. Install flange bolts (B) and flange nuts (C), securing the first roof flashing section (A) to the roof
panel ribs.
NOTE:
Only the first roof flashing section is installed using only six of the required flange bolts and
nuts. Any remaining unfilled holes will be filled when the last roof flashing section is installed.
Figure 8-27
Installation of the first roof flashing section
A
Roof flashing (CTR-1574)
C
5/16 in. flange nut (S-3611)
B
5/16 x 1 flange bolt with sealing washer (S-
10260)
D
Outer center collar (CTR-1603)
3. Place a strip of rope caulk (E) along the edge of the installed roof flashing (A) where the next roof
flashing will overlap.
4. Align the holes along the edge of the next roof flashing (A) with the previously installed roof flashing
holes.
5. Install flange bolts (B) and flange nuts (C), securing the two roof flashing sections (A) together.
124
PNEG-4472
72 Ft Diameter Z-Tek Bins
Содержание 40-SERIES
Страница 6: ...NOTES 6 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Страница 18: ...NOTES 18 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Страница 26: ...NOTES 26 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Страница 34: ...NOTES 34 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Страница 72: ...NOTES 72 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Страница 168: ...NOTES 168 PNEG 4472 72 Ft Diameter Z Tek Bins ...