Figure 8-8
Installing a temperature cable bracket
A
Left-hand roof rafter (CTR–0873)
F
1/2 in. flange nut (S-10253)
B
10 in. temperature cable bracket (CTR-0973)
G
Right-hand roof rafter (CTR–0873)
C
Right purlin clip (CTR-0950)
H
10 in. temperature cable bracket
(CTR-0013)
D
Left purlin clip (CTR-0876)
I
Right purlin clip (CTR-0100)
E
1/2 x 1-3/4 in. flange bolt (S-10252)
J
Left purlin clip (CTR-0099)
3. Install a quick link (C) to each cable bracket (B) to support the temperature cables.
IMPORTANT:
Do not attach weights to the temperature cables; secure the bottom of cables to the
floor with light twine. No roof rafter shall support more than one cable.