Water Softener
WINNI-mat
®
VGX
Order no. 215 188 040-inter Edited by: KONS-pha-rg G:\BA-188040-INTER-VGX.DOC
26
E Start-up
The work described below may only be performed by trained experts.
We recommend having Grünbeck‘s technical service start up the sys-
tem.
1 | How to prepare the brine tank
Fill the brine tank:
VGX 9, 14 and 19 (fill in 6.5 litres of water into the brine tank – up
to approx. 1 cm above the sieve bottom).
Fill in salt tablets
Note:
In case of overfilling (> 6.5 litres), the time in step „salting“may
be exceeded and the error signal ER7 will be indicated. Acknowledge
the error after termination of the regeneration by pressing the program
key (regeneration is released).
Attention!
Impurities in the salt may cause malfunctions at the brine
valve and the injector of the control valve. Only use salt tablets as per
EN 973 type A.
Note:
The salt level in the brine tank must always be higher than the
brine level.