2.2
How to set the operating parameters
Principle
In order to make settings, a programming level must be called first
(user programming level: key 1, service programming level:
keys 1 + 2).
On the programming level, key 3 switches to the next, key 2 to the
previous menu. When the parameter which is to be changed is
reached, the menu can be opened by pressing key 1, the display is
blinking. In the open menu (blinking display), keys 2 and 3 switch to
lower resp. higher values. When the correct value (blinking) appears
in the display, it may be stored by pressing key 1. Thereby, the menu
will be closed and the display shows the set value as permanent dis-
play.
When all required settings have been made, the programming level is
closed by pressing keys 2 + 3 simultaneously and the display returns
to the basic function (time). The system also returns to the basic level
if no entry is made for more than 1 minute. Entries which had not
been stored are lost.
Note:
Instructions in bold print are essential for the continuation of the
work. All other instructions may be omitted if the value in the display
shall remain unchanged.
Basic settings (user programming level)
At start-up, the basic settings must be co-ordinated with the local
conditions. In case of varying raw water quality, the value has to be
adapted.
On the basic level, the display shows the operating status of the ex-
changer and the time stored in the system. First, call the user pro-
gramming level
1. Hold down the „Program“ key (1) for more than 1 second.
The display shows the hour. If the display corresponds with the actual
time, steps 2. – 4. can be omitted.
2. Press „Program“ key (1).
The display starts blinking.
3. Set actual time (hour). In order to do so:
decrease the hours with „Hand Reg.“ key (2)
OR
increase the hours with „Info“ key (3).
4. Store the setting by pressing key (1).
The display shows the hour without blinking.
5. Press „Info“ key (3) in order to switch to the next menu.