INSTALLATION INSTRUCTIONS — 

POINT OF USE WATER HEATERS

EPU - HW

Содержание EPU-HW

Страница 1: ...INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU HW ...

Страница 2: ...CONTENTS PAGE INSTALL CONTENT 2 Introduction 3 Component List Technical Specification 4 Component Diagram 5 Installation 9 Commisioning Maintenance 10 Warranty Policy 01 ...

Страница 3: ...ed in this manual Particular attention should be paid to the section headed Installation This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervison or instruction concerning use of the appliance in a safe way and understand the hazards involved Children sh...

Страница 4: ... 7MPa Water connection 1 2 BSP male IP Code IPX4 Inlet and outlet distance 90mm Dimensions 220 x 170 x 90mm Weight 1 6kg ErP Band A Load Profile XXS AEC 509 3kWh COMPONENT CHECKLIST Before commencing installation check that all the following components have been supplied with water heater Heater Spout Fitting instructions 03 ...

Страница 5: ...COMPONENT DIAGRAM 1 Inlet 2 Outlet 3 Water container assembly 4 Flow valve To close turn clockwise 5 Flow switch 6 Cable clamp 7 Main connector block 8 Thermal cut out 1 2 3 8 4 5 6 7 04 Figure 1 ...

Страница 6: ...a maximum of 0 7MPa 7bar DO NOT operate the appliance if Water ceases to flow during use Water has entered inside the unit because of an incorrectly fitted cover The appliance is damaged In all the above cases turn off mains power and isolate water supply ISOLATE the electrical and water supplies before removing the cover ISOLATE the electrical and water supplies BEFORE proceeding with installatio...

Страница 7: ...ational and applicable national and local plumbing regulations The supply pipe must be flushed to clear debris Cold water connection inlet is on the right side of the unit hot water connection outlet is on the left side of the unit which need to be connected with the spout The outlet must not be connected to any tap or fitting other than those specified All plumbing connections must be completed a...

Страница 8: ...ouble pole isolating switch with a contact separation of at least 3mm in each pole and a minimum rating of 13Amp must be incorporated in the wiring of the appliance It is recommended that a residual current device RCD is used to provide additional protection against electric shock This may be part of the consumer unit or a separate unit The handwash must be connected to its own independent electri...

Страница 9: ...Side Entry Wall Entry 08 Figure 2 ...

Страница 10: ...ired level using the knob on the front cover of the unit Explain to the user how the unit works and familiarise him or her with its use Advise the user about possible hazards Hand over these instructions to be kept for future reference MAINTENANCE The handwash is designed for a very long service life Actual life expectancy will vary with water quality and use The unit itself does not require any r...

Страница 11: ...a competent person in accordance with the Installation User instructions all relevant Code of Practice Regulations in force at the time of installation and that all necessary controls and safety devices have been fitted correctly 2 The appliance has only been used for heating potable water 3 The appliance has been maintained as detailed in the Installation and User Instructions 4 The product has b...

Страница 12: ... the details given in this document are subject to alteration without notice REF 025208 Everflo Hand Wash Installation Manual English February 2017 Everflo Unit 11 Capital Industrial Estate Crabtree Manorway South Belvedere Erith Kent DA17 6BJ Sales Tel 0208 3123720 Technical Helpline 0330 999 0035 sales everflocylinders co uk www everflocylinders co uk ...