Water Softener
Weichwassermeister
®
GSX 5, GSX 10, GSX 10-I
Order no. 075 187 970-inter Edited by: KONS-nkes-mrie G:\BA-187970-INTER_GSX 5-10.DOC
39
Index Parameter
unit
Factory-
setting
Setting
range
Remarks
0
Hardness unit
L1
1 = °dH,
2 = °f,
3 = mol/m³
Applies to the raw water and soft
water hardness as well as to the ca-
pacity number
1 System
data
record CA
Depending
on system
type
CA71:
Weichwassermeister
®
GSX 5
CA72: Weichwassermeister
®
GSX 10
CA73: Weichwassermeister
®
GSX 10-I
All other data records are reserved.
Warning:
Modifications may only be
made by Grünbeck’s technical ser-
vice/authorised service company!
2 Capacity
number
[m³x°dH] Depending
on system
type
Display
only
CA71: 5.0
CA72: 10.0
CA73: 10.0
3 Turbine
water
meter constant
[l/pulse] Depending
on system
type
Display
only
CA71: 0300 is displayed
CA72: 0300
CA73: 0300
4
Home in on ref-
erence position
of transfer valve
0
0 … 1
Started by reprogramming to the
value 1. An ongoing regeneration is
aborted by this.
Attention:
Modifications may only
be made by Grünbeck’s technical ser-
vice/authorised service company!
5
Home in on ref-
erence position
of regeneration
valve
0
0 … 1
6 Displayed
seg-
ments regenera-
tion unit / brine
tank
0
0 … 1
Are activated by reprogramming to
the value 1.
7 Green
LED
„OK / ON“
1
0 … 1
Is switched off for good by repro-
gramming to the value 0.
8 Disinfection
program
0
0 ... 1
Is started by reprogramming to the
value 1.
Attention
: Also observe the instruc-
tions for the disinfectant! The disin-
fection may only be performed by
Grünbeck’s technical service/ author-
ised service company
9
Start twin re-
generation
(both exchang-
ers, one after
the other)
0
0 .. 9
1 = immediate start
2 = start after a delay period of 2
hours
9 = start after a delay period of 9
hours.
Table F-3: Parameters on Installer level 290