background image

 Instruction manual 1.0.0 rev1 en 

 

 

GROW

BASE 

 

 

6

 

 

Specified normal operation 

This digital environmental controller is designed for speed controlling of fans and switching a 

number of other devices. In addition, lights with a 1-10V/1-10V input can be dimmed. 
Depending on the mode of operation, the controller’s power sockets may be used for 

connecting devices below:  

 

Power sockets „Multifunctional Out 1-4“: 

o

 

humidifier/ dehumidifier 

o

 

lights* 

o

 

irrigation pumps 

o

 

circulation fans 

o

 

CO

 valves/ generators (230V) 

o

 

heating mats 

o

 

chillers 

o

 

Regular duct fans with running capacitor* 

The following devices can be connected to the laterally RJ45 jacks: 

 

RJ45 jacks „In/Out“: 

o

 

humidity and temperature sensor (shipped with the controller) 

o

 

CO

 sensor (CarbSense) 

o

 

negative pressure sensor (PresSense) 

o

 

temperature sensor for heating matt 

 

RJ45 jacks „EC-Fans“: 

o

 

voltage controlled EC fans 

 

RJ45 jack „Lights 0-10V“: 

o

 

lights with 0-10V/1-10V input 

o

 

relays/ contactors 12-24V 

 
The device is not suitable for controlling any other equipment.  

 

The mains cable of an EC fan may not be connected to a power socked on the controller. 
It should be connected to a standard power socked that is always on. The speed control 

and switch off is done with the signal from the corresponding RJ45 jack. 

 

Warning!

 

If the “intake” mode is selected for the “Multifunctional Out 1-4” output, only standard 
fans may be connected. Other devices may be damaged in the “intake” mode. When 
shipped, the functions of “Multifunctional Out 1 and 2” are set to “intake” and “exhaust”. 

 

To meet the European EMC directive, the technique used to control the regular duct fans 
may be used up to a maximum 600W. Do not connect devices with a power above 600W 

in “intake” or “exhaust” mode. 

 

Always ensure that the maximum output power of the individual outputs is not exceeded. 
Please find further information on the device’s label or chapter 11of this manual. 

 

Avoid exposing the temperature and humidity sensor to humility above 95% RH as the 
sensor may become damaged. 

 

Do not connect fans with an integrated rpm control. (e.g. temperature controlled) 

*The sockets of 

GROW

BASE

 are not optimized for switching LED luminaires or energy-saving 

lamps. To guarantee that the luminaires are completely switched off, the 4th socket of the 

GROW

BASE 

 PRO

 controller should be used for LED luminaires or energy-saving lamps. 

Содержание GROWBASE

Страница 1: ...winnerstr 46 60388 Frankfurt Germany Mail info growcontrol de Web www growcontrol de Instruction Manual GROWBASE Multifunctional digital climate controller with timer functions and CO control For AC a...

Страница 2: ...observe the relevant information Store this instruction manual and make it accessible to all users Ensure that you include this instruction manual when handing over the device to third parties With k...

Страница 3: ...detail 13 7 1 Info level 13 7 2 Climate 15 7 3 CO2 16 7 4 Ventilation 18 7 5 Timing 21 7 6 Lights 22 7 7 Advanced setup 23 7 8 System setup 23 7 9 Multifunctional Out 26 7 10 Firmware update 26 8 Appe...

Страница 4: ...well as plug connections for their proper condition prior to each use Check the proper status of all parts connected to the device Do not use the device if it is damaged Do not pull on the cables to...

Страница 5: ...of fire if the device is used improperly or these instructions for use are ignored Never use the device near highly flammable substances Operation Warning The device is only intended for the purpose d...

Страница 6: ...to a power socked on the controller It should be connected to a standard power socked that is always on The speed control and switch off is done with the signal from the corresponding RJ45 jack Warni...

Страница 7: ...ors is able to control the CO level in the grow room with a CO sensor CARBSENSE connected is able to calibrate the connected CO sensor ensures a constant negative pressure in the grow room avoiding th...

Страница 8: ...the included screws dowels and drilling template Provided that the sizing of the connected utilities is appropriate and the fresh air temperature is sufficiently low The tolerance is related to the re...

Страница 9: ...0V dimming of lights and Multifunctional Out 5 4 RJ45 jack for exhaust EC fan 5 RJ45 jack for intake EC fan 6 5xRJ45 jack for sensors and PowerExtenders 7 USB A Port for firmware updates 8 11 Programm...

Страница 10: ...nctions according to your requirements 4 Connect the EC fans to the RJ45 jacks labelled intake and exhaust 4 5 using a suitable cable 5 Connect other accessories sensors lights with 0 10 1 10V etc to...

Страница 11: ...ev1 en GROWBASE 11 Menu overview Setup Info 1 Start Climate setup 2 System setup 8 Advanced setup 7 Cancel return home Save return home Save apply Lights setup 6 Timing setup 5 Ventilation setup 4 CO2...

Страница 12: ...d and the previous screen will be displayed To jump from the level Info directly to the level Setup press the rotary switch a bit longer and then release it while an Info screen is displayed Longer th...

Страница 13: ...ng the operation condition is displayed This screen is the home screen It shows the current temperature Temp and relative humidity RH This screen shows the current CO concentration detected by the CO...

Страница 14: ...e percent value represents the power transmitted to the fan The rpm value represents the fan s actual rpm The rpm value is not transmitted from all EC fans The rpm value can only be displayed if the c...

Страница 15: ...switch while this screen is displayed Climate In this section all setpoints desired values associated with temperature or humidity can be configured For each temperature or humidity setpoint a separa...

Страница 16: ...This will extract the humidity from the grow room given that the humidity of the fresh air is lower when inside the grow room This function is independent of whether a humidifier or dehumidifier is co...

Страница 17: ...eight width m m m m Enter the flow set on the CO armature or specified for your CO generator Unit l min litres minute The table below can be used as rough reference for the CO flow Room volume CO flow...

Страница 18: ...ve pressure can be set Separate values for day and night are available The factory settings are a good starting point for many setups Considerations for the optimum settings are Reasonable noise of th...

Страница 19: ...g is entered the message AC intake exhaust OFF is displayed In order to not turn off the corresponding fan the value for intake exhaust MIN MAX must be grater then the corresponding value AC turnoff I...

Страница 20: ...ue of 10 is set this means that the intake fan will always turn 10 less compared to the exhaust fan With a pressure sensor connected The setting limits the speed of the intake fan compared to the exha...

Страница 21: ...Event Timer times event start and event duration can be set e g event 1 start 14 30 hh mm event 1 duration 00 10 00 hh mm ss One or more events can be assigned to one power socket e g function out 1 e...

Страница 22: ...or 1 10V input For lights with a 0 10V input the brightness control as well as the turnoff is done with the 0 10V signal The mains supply of the lights doesn t have to be switched off in order to swi...

Страница 23: ...low the fan speed can be reduced is depending on the particular AC fan To avoid driving the AC fan to low a value for switch off is defined In order to not turn off the corresponding fan the value for...

Страница 24: ...average minimum maximum It defines which value is used for the corresponding function For these values settings are available RH Humidity captured by sensors RH T T Temperature captured by sensors RH...

Страница 25: ...fter a successful transfer of the filter value a message similar to the Apply calibration In order to restore all factory settings choose OK and confirm by pressing the rotary switch Please note that...

Страница 26: ...The sockets of GROWBASE are not optimized for switching LED luminaires or energy saving lamps To guarantee that the luminaires are completely switched off the 4th socket of the GROWBASE PRO controller...

Страница 27: ...rmat The firmware file has to be on the top level of the folder structure It may not be saved inside a folder The number of firmware files saved on one USB drive is limited to 20 files The name of a f...

Страница 28: ...ive pressure value If the value is too high the speed of the supply air fan will oscillate With a small value the negative pressure control reacts less responsive to changes in the currently measured...

Страница 29: ...er is following a PD or a P algorithm Hysteresis humidifier Set the hysteresis for the control of a humidifier here The hysteresis determines how often the humidifier is switched on and off and how ex...

Страница 30: ...connect lights with an 0 10 1 10V input or DC relays contactors use a suitable cable available as an accessory The assignment of the RJ45 jack labelled Lights 0 10V is shown in the following figure l...

Страница 31: ...mation only and has no influence on the control or function Function colour EC standard Pin RJ45 10V red 3 0 10V yellow 4 GND 0V blue 5 Pulse rpm white 6 Table 1 What to do if there are problems Probl...

Страница 32: ...r exhaust air AC The socket Multifunctional Out 4 is not switched on The 2nd power cable for the 4th socket is not connected Connect both power cables to the controller Table 2 Technical data Dimensio...

Страница 33: ...ng this period is to repair or replace the defective part or product with a comparable part or product at GrowControl s sole discretion Except for such replacement the sale or other handling of this p...

Страница 34: ...ry Version 1 0 0 rev1 en created on 26 10 2021 English translation Version 1 0 0 created on 13 06 2020 First release German version Refers to firmware version 5045 0 00 04 and higher Version 1 0 0 rev...

Страница 35: ...Instruction manual 1 0 0 rev1 en GROWBASE 35 V1 0 0 rev1 en GrowControl Excepting errors and changes...

Отзывы: