This screen shows the minimum and
maximum temperature values (T) that have
occurred since the last reset.
To reset the saved minimum and maximum
values, press the rotary switch while this
display is shown. After resetting, the home
screen will be displayed.
If the desired CO
₂
concentration cannot be
achieved within 45 minutes, this suggests
that there is a problem with the CO
₂
supply, such as an empty CO
₂
bottle.
The higher temperature in CO
₂
mode could
be harmful for your plants without a
sufficient CO
₂
concentration. Therefore,
the controller will switch to the regular
“
day mode
”
without CO
₂
dispensing and
the warning “check CO2 supply” will be
displayed.
To delete the warning and return to
operation in CO
₂
mode, press the button
while this screen is displayed.
These screens show the current fan speed
of the EC fans. The “percent value”
represents the power transmitted to the
fan. The “rpm value” represents the fan’s
actual rpm. The rpm value is not
transmitted from all EC fans. The rpm value
can only be displayed if the corresponding
signal is transmitted by the EC fan and is
supported by the cable. The cable must
have at least 4 wires to support this
function. The rpm value is for information
only and has no influence to the function.
rpm = revolutions per minute
The screens Multi Out 1 to Multi out 5
display the function that is assigned to
each power socked or the DC output (Multi
Out 5). Also, the current state of each
output is displayed. If one or more
PowerExtenders are connected, the
number of available outputs is increased
accordingly.
This display informs about the current
state of the interval timer. It indicates
whether the next switching is ON or OFF
T MIN
C
24.6
A
C i
T MAX
C
26.3
A
C
BC
Press for
F
reset MIN/MAX
BC
Press to reset
F
CO2 warning
BC
Intake EC
C
i
2510rpm
62
A
BC
Exhaust EC
C
i
2139rpm
72
A
BC
Multi Out 1
C
i
Intake AC 62
A
BC
Interval ON
i
in
C
00
C07C56
BC