Instruction manual 1.0.0 rev1 en
GROW
BASE
32
A small inductive load
(e.g. contactors, small
pumps) connected to
one of the Multi Out 1-
3 sockets will not
switch off
The standard configuration
is not suitable for the
connected equipment
Contact our support to get
information on how to solve the
problem
An EC fan connected to
the controller is not
running correctly
The mains cable of the EC
fan is incorrectly connected
to a socket set to supply
air/exhaust air AC
Connect the power cord of the
EC fan to a normal power outlet.
Never connect the mains cable
of an EC fan to a socket on the
controller that is set to supply
air/exhaust air AC!
The socket
Multifunctional Out 4 is
not switched on
The 2nd power cable for
the 4th socket is not
connected
Connect both power cables to
the controller
Table 2
Technical data
Dimension (LxWxH) without cables
190mm x 170mm x 120mm
Length of sensor cable temperature (T)/ relative
humidity (RH)
ca. 5m
Length of mains cable
ca. 2m
Power supply
100-240V~ 7A 50-60Hz
Maximum power per output “Multifunctional
Out 1-4“
600VA(W)@230V 310VA(W)@120V 2.6A
Maximum power “Multifunctional Out 1+2+3+4“ 1600VA(W)@230V 840VA(W)@120V 7A
Output Multifunctional Out 5
12-24V DC 1A max.
Output 0-10V outputs max.
20mA
International protection marking/Protection class IP42/
Repetitive sensor accuracy T/RH
±0.1%RH/±0.2°C
Absolute sensor accuracy T/RH
±2%RH/±0.2°C
Range for setpoint temperature
10-50°C
Allowed ambient temperature
10-40°C
Table 3