Instruction manual 1.0.0 rev1 en
GROW
BASE
16
Temperature heating mat:
These values define the setpoint for the temperature control of a
heating mat. The sensor reading relevant for this function is captured by a sensor available as
accessory.
Chiller:
An output configured as “Chiller” (Multifunctional Out 1-5) is switched on if the
desired room temperature is exceeded by 2°C and is switched off if the room temperature is
1°C below the desired room temperature.
Set the desired humidity value (RH).
Separate values for day and night are
available.
Set the desired temperature values (T) for
the room air. Separate values for day and
night are available.
Set the temperature for a heating mat
here. You can set a fix temperature or a
temperature relative to the ambient
temperature.
“fix” means a fixed temperature
“amb +” means a temperature relative to
the ambient temperature.
Separate values for day and night can be
set.
When the desired humidity (RH) is
exceeded, depending on the selected
mode the fan speeds can be increased. This
will extract the humidity from the grow
room, given that the humidity of the fresh
air is lower when inside the grow room.
This function is independent of whether a
humidifier or dehumidifier is connected to
one of the power outputs.
Three modes are available:
Medium
– When the desired humidity is
exceeded by 10% RH, the air flow will be
increased. A deviation of 1.5°C compared
to the desired temperature will be
tolerated.
High
- When the desired humidity is
exceeded by 5% RH, the air flow will be
increased. A deviation of 3°C compared to
the desired temperature will be tolerated.
Off
– The airflow will not be increased
when the desired humidity is exceeded.
CO2
In this section the settings for the CO
₂
control can be configured.
With our CO
₂
s
ensor
CARB
SENSE
, the CO
₂
concentration of the room air can be controlled.
The CO
₂
dosing can be done by using a CO
₂
bottle or by using a CO
₂
generator. The CO
₂
dosing is done during daytime only.
On basis of the settings, the control algorithm calculates how long the CO
₂
valve has to be
opened or how long a CO
₂
generator has to be switched on in order to reach the desired CO
₂
Set desired RH
F
dayC 65A
Set desired T
F
dayC 65A
T h-mat day
C
F
fix
28
A
C
BC
Set dehumid
F
mode
C
low
BC