Model G0820 (Mfd. Since 12/16)
-75-
Blade Tilt Calibration
The blade tilt stops are calibrated at the factory,
but they can be recalibrated if they change during
the life of the machine. The 0° stop positions the
blade square to the table.
Tools Needed
Qty
Hex Wrench 3mm .............................................. 1
Open-End Wrench 8mm.................................... 1
Machinist's Squares, 90° & 45° ...................1 Ea.
0° Stop
1. DISCONNECT MACHINE FROM POWER!
2. Move blade tilt to 0° and raise main blade as
high as it will go.
3. Open cabinet door and identify stop nuts
shown in
Figure 153.
4. Use machinist's square to check if main blade
is square to table (see
Figure 154).
Figure 155. Tilt scale cable hex nuts.
a. If main blade is not square to table, loos-
en the two set screws on 0° stop nut, then
loosen stop nut away from leadscrew
collar.
b. Adjust main blade tilt angle so that it is
square to table.
c. Thread 0° stop nut against leadscrew col-
lar and retighten set screws.
45° Stop
Use a similar procedure for the 45° stop nut
shown in
Figure 153, as previously instructed for
the 0° stop nut.
Tilt Scale Calibration
If necessary, the blade tilt scale on the front of the
saw can be adjusted by using the hex nuts shown
on the tilt scale cable in
Figure 155. These are
accessed inside the cabinet.
Table
90° Square
Blade
Figure 154. Machinist's square against blade
and table.
Figure 153. Blade tilt stop nuts.
Leadscrew
Collar
Tilt Scale
Cable Hex Nuts
0° Stop
Nut
45° Stop
Nut
Содержание G0820
Страница 104: ......