-36-
Model G0820 (Mfd. Since 12/16)
Figure 62. Up-close view of power supply
terminal inside junction box.
R and T
Connections
Ground
Power
Connection
Junction Box
Do not swap "R" or "T" wires with ground
wire inside power connection junction
box. Doing so will electrify machine frame,
which could cause electrocution. Make sure
incoming ground wire is only connected to
left-most terminal post in the power con-
nection junction box so machine is properly
grounded.
7. Press Emergency Stop button on front of
machine to turn machine
OFF.
8. WITHOUT resetting Emergency Stop button,
press ON button. Machine should not start.
— If machine does start (with Emergency
Stop button pushed in), immediately dis-
connect power to machine. Emergency
Stop button safety feature is not working
correctly. This safety feature must work
properly before proceeding with regular
operations. Call Tech Support for help.
9. Reset Emergency Stop button on front of
machine.
11. Move sliding table all the way right, then open
blade cover, as shown in
Figure 64. This
activates blade cover safety switch to prevent
saw from starting while cover is open.
Figure 64. Blade cover open.
Blade Cover
12. While staying safely away from blade, reset
Emergency Stop button, then try to start main
blade and scoring blade.
— If blades do not start, blade cover safety
switch safety feature is working correctly.
— If blades do start (with blade cover open),
immediately turn machine
OFF and dis-
connect power. The blade cover safety
switch safety feature is not working cor-
rectly. This safety feature must work prop-
erly before proceeding with regular opera-
tions. Call Tech Support for help.
13. Carefully close blade cover, then move slid-
ing table back to center of machine.
10. Repeat Steps 7–9 with Emergency Stop but-
ton on rear of cabinet (see
Figure 63).
Figure 63. Emergency Stop on cabinet.