Model G0772 (Mfd. Since 05/15)
-51-
Replacing & Aligning
Scoring Blade
The scoring blade rotates in the opposite direc-
tion of the main blade and makes a shallow cut in
the workpiece surface to help prevent workpiece
tear-out.
The scoring blade set included with the Model
G0772 consists of an inner and outer blade with
internal shims (see
Figure 92). The shims are
provided to match the scoring blade kerf with the
kerf thickness of the main blade.
Figure 92. Example of scoring blade set with
shims.
Replacing Scoring Blade
Tools Needed
Qty
Wrench 10mm ................................................... 1
Wrench 22mm ................................................... 1
To replace scoring blade:
1. Adjust blade tilt to 0° and raise both blades all
the way up.
2. DISCONNECT MACHINE FROM POWER!
3. Raise blade guard and move it away from
blade.
4. Move sliding table all the way forward, and
open lower blade cover.
5. Place 10mm wrench around flats of arbor
shaft, and use 22mm wrench to loosen arbor
nut by turning counterclockwise (see
Figure
93).
Figure 93. Scoring blade removal.
6. Remove arbor nut, flange, and scoring blade
set.
7. Stack new scoring blade to same kerf thick-
ness as main blade.