Model G0772 (Mfd. Since 05/15)
-37-
Before the machine can be connected to the
power source, an electrical circuit and connec-
tion device must be prepared per the
POWER
SUPPLY section in this manual; and all previous
setup instructions in this manual must be com-
plete to ensure that the machine has been assem-
bled and installed properly. The disconnect switch
installed by the electrician (as recommended) is
the primary means for disconnecting or connect-
ing the machine to the power source.
Power Connection
To connect saw to power:
1. Open electrical panel door (see Figure 62)
with included key.
2. Insert incoming power wires where strain
relief is located on cabinet next to electrical
panel door.
During next step, make sure incoming ground
wire is connected to left-most terminal post
in the power junction box so machine is
properly grounded. An ungrounded or
improperly grounded machine may have an
electrified frame which could cause electro-
cution when touched.
Electrocution, fire, shock,
or equipment damage
may occur if machine is
not properly grounded
and connected to power
supply.
Note About Phase Converters: Avoid using a
static phase converter to supply 3-Phase power
for this machine, as it could damage or decrease
the life of sensitive electrical components. If you
must use a phase converter, only use a rotary
phase converter that is sized at least 50% larger
than the largest HP rating of this machine. If using
a phase converter to supply power, only connect
the manufactured leg or "wild wire" to the "S"
terminal (see location on
Page 87). The S terminal
can handle power fluctuations because it is wired
directly to the motor.
Figure 62. Location of electrical panel and strain
relief.
Electrical Panel Door
Strain Relief
3. Connect ground wire to ground terminal, then
connect incoming power wires to bottom R,
S, T terminals shown in
Figure 63.
Figure 63. Terminal locations to connect
incoming power wires and ground wire.
Incoming Power
Terminals
Ground
Terminal