26
DIAGNOSTIC CODES CHART (CONT.)
Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then
disappear.
Code
Meaning
Solution
Saved
60
Minimum number of monitored entrapment
protection devices (one) not installed
Review monitored entrapment protection device connections
NO
61
CLOSE EYE/INTERRUPT held more than 3
minutes
Check wired input on main control board; check for alignment or
obstruction
YES
62
CLOSE EDGE held more than 3 minutes
63
OPEN EYE/EDGE held more than 3 minutes
64
CLOSE EYE/INTERRUPT held more than 3
minutes
Check wired input on expansion board; check for alignment or
obstruction
YES
65
CLOSE EYE/EDGE held more than 3 minutes
66
OPEN EYE/EDGE held more than 3 minutes
67
Wireless edge triggered more than 3 minutes
Check wired input for wiring issue or obstruction
YES
68
Wireless edge loss of monitoring
Check wireless edge inputs
YES
69
Wireless edge triggered
IF an obstruction occurred, no action required. If an obstruction
did NOT occur, check inputs and wiring.
NO
70
CLOSE EYE/INTERRUPT triggered, causing
reversal, preventing close, or resetting TTC
IF an obstruction occurred, no action required. If an obstruction
did NOT occur, check alignment, inputs, and wiring on main
control board
NO
71
CLOSE EDGE triggered, causing reversal,
preventing close, or canceling TTC
72
OPEN EYE/EDGE triggered, causing reversal
or preventing opening
73
CLOSE EYE/INTERRUPT triggered, causing
reversal, preventing close, or resetting TTC
IF an obstruction occurred, no action required. If an obstruction
did NOT occur, check alignment, inputs, and wiring on
expansion board
NO
74
CLOSE EYE/EDGE triggered, causing reversal
and preventing close or canceling TTC
75
OPEN EYE/EDGE triggered, causing reversal
or preventing opening
80
Close input (EYE/EDGE) communication fault
from other operator
Check inputs and communication method between operators,
either wired bus or radio. Ensure operator is powered. May have
to erase the wireless communication and reprogram the two
operators
YES
81
Open input (EYE/EDGE) communication fault
from other operator
82
Close input (EYE/EDGE) communication fault
(expansion board)
Check the connections between the main board and the
expansion board
YES
83
Open input (EYE/EDGE) communication fault
(expansion board)
91
Force Reversal (Operator 1)
Check for obstruction. If no obstruction, check that the
mechanical assembly is engaged and free to move. See section
on Limit and Force Adjustment, and Obstruction Test
YES
93
RPM / STALL Reversal (Operator 1)
Check for obstruction. If no obstruction, check the operator
wiring and that the mechanical assembly is engaged and free to
move. Replace APE assembly
YES
99
Normal Operation
No action required
YES
Grifco System
Installed System
Informational
TROUBLESHOOTING
External Entrapment
Protection
(Safety Input Event)
Inherent Entrapment
Protection
(Force Based Event)