background image

2

 

WARNING

:

Important safety instructions

It is important for the safety of persons to follow all instructions.

SAVE these instructions

WARNING

CAUTION

WARNING

This commercial door operator has been designed and tested to offer safe service provided it is installed, operated, maintained and tested 
in strict accordance with the instructions and warnings contained in this manual.

Mechanical

Electrical

When you see these Safety Symbols and Signal Words on the 
following pages, they will alert you to the possibility of serious 
injury or death if you do not comply with the warnings that 
accompany them. The hazard may come from something 
mechanical or from electric shock.

When you see this Signal Word on the following pages, it will alert 
you to the possibility of damage to your commercial door and/or 
the commercial door operator if you do not comply with the 
cautionary statements that accompany it.

Keep commercial door balanced. Sticking or binding doors must be 

repaired. Commercial doors, door springs, pulleys, brackets and their 

hardware are under extreme tension and can cause serious personal 

injury. Do not attempt to loosen, move or adjust them. Call for commercial 

door service.

Permanently fasten all supplied labels adjacent to the wall control as a 

convenient reference and reminder of safe operating procedures.

Activate operator only when the door is in full view, free of obstructions 

and operator is properly adjusted. No one should enter or leave the 

building while the door is in motion.

An electrician must disconnect electric power to the commercial door 

operator before making repairs or removing covers.

The actuating member of a biased-off switch is to be located within direct 

sight of the door but away from moving parts. Unless it is key operated, it 

is to be installed at a minimum height of 1500mm and not accessible to 

the public.

Make sure that people who install, maintain or operate the door follow 

these instructions. Keep these instructions in a safe place so that you can 

refer to them quickly when you need to.

This appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not play with the 

appliance.

If the operator is installed at a height less than 2.5 metres from  floor level 

or any other level from which the operator can be accessed (eg 

mezzanine) the installer is responsible to fit guards to the operator to 

prevent access to the chain drive.

Use the commercial door operator for its intended purpose. The GSD-

SDO S-Drive operator is designed lifting spring-balanced sectional doors.

Disengage all existing commercial door locks to avoid damage to 

commercial door. Install the wall control (or any additional push buttons) in 

a location where the commercial door is visible during operation . Do not 

allow children to operate push button(s) or remote transmitter(s). Serious 

personal injury from a closing commercial door may result from misuse of 

the operator.

Do not wear rings, watches or loose clothing while installing or servicing a 

commercial door operator.

To avoid serious personal injury from entanglement, remove all ropes 

connected to the commercial door before installing the door operator.

After the installation a final test of the full function of the system and the 

full function of the safety devices must be done.

When operating a biased-off switch, make sure that other persons are 

kept away.

The operator cannot be used with a driven part incorporating a wicket 

door (unless the operator cannot be operated with the wicket door open).

Motor may become hot during operation. Appropriate clearance and/or 

shielding should be supplied by the installer to ensure any cabling, wiring 

and/or other items cannot come in contact with the motor. If temperature 

rise exceeds 50°C all fixed wiring insulation must be protected, for 

example, by insulating sleeving having an appropriate temperature rating.

THESE ARE IMPORTANT SAFETY INSTRUCTIONS. FOLLOW ALL INSTRUCTIONS AS INCORRECT

INSTALLATION CAN LEAD TO SEVERE INJURY OR DEATH

Installation and wiring must be in compliance with your local building and 

electrical codes. Connect the power supply cord only to properly earthed 

mains. If the supply cord is damaged, it must be replaced by the 

manufacturer, its service agent or similarly qualified persons in order to 

avoid a hazard.

Moisture and water can destroy the electronic components. Make sure 

under all circumstances that water moisture or storage moisture cannot 

penetrate the electronics. The same applies for openings and cable 

entries.

SAFETY SYMBOL AND SIGNAL WORD REVIEW

Содержание GSD-R2.4M

Страница 1: ...CIAN ONLY This operator is compatible with Security 2 0 accessories OPERATOR REQUIRES GRIFCO MONITORED ENTRAPMENT PROTECTION OPERATOR REQUIRES GRIFCO MONITORED ENTRAPMENT PROTECTION Commercial Section...

Страница 2: ...on responsible for their safety Children should be supervised to ensure that they do not play with the appliance If the operator is installed at a height less than 2 5 metres from floor level or any o...

Страница 3: ...ING 10 TYPES OF MONITORED ENTRAPMENT PROTECTION 11 SELECTION OF ENTRAPMENT PROTECTION SYSTEM 11 COMMISSIONING ENTRAPMENT PROTECTION SYSTEMS 12 FORCE SETTING AND FINE ADJUSTMENT 13 TYPES OF SECURITY 2...

Страница 4: ...s Rail Part No 2 4m GSD R2 4M 3 6m GSD R3 6M 6 0m GSD RKIT rail angle not supplied Maximum Door Weight 315 5 kg balanced door Maximum Door Area 26m Travel Speed 20cm per second Maximum Duty Cycle Cont...

Страница 5: ...NECTION RESET BUTTON ACCESS CONTROL DEVICE EXTERNAL TERMINAL BLOCK AC POWER SWITCH EMI BOARD INTRODUCTION PE Beams Sold Separately Make sure the door opens and closes smoothly Door should stay in the...

Страница 6: ...mitters and the network 7 TIMER TO CLOSE dial The TIMER TO CLOSE TTC dial can be set to automatically close the door after a specified time period The TTC is factory set to OFF If the TTC is set to th...

Страница 7: ...le is clear the door will continue to close 5 AUX RELAY Switches Set the AUX RELAY switches as need ed to obtain the desired function as shown on pages 20 21 6 EYE EDGE Switches Set the EYE EDGE switc...

Страница 8: ...7 Attach the push arm to the trolley test emergency release rope is operational Attach the J bar to the push arm 8 Attached J bar to door bracket after following STEP 3 on the next page Header Bracke...

Страница 9: ...egative terminal of the other battery 5 Insert the batteries as shown 6 Reattach the battery cover 7 Insert the J15 plug back into the control board This will power up the control board NOTE You may s...

Страница 10: ...n you program the limits but can be fine tuned using the REVERSAL FORCE dial on the control board refer to Fine Tune the Force section to compensate for environmental changes The limit setup LEDs loca...

Страница 11: ...iant safety sensors relying on a non monitored normally closed contact can be bypassed or fail to operate in the event of damage or tampering Entrapment Protection Systems must be monitored to form pa...

Страница 12: ...tion PE beams with selectable functionality EYE EDGE and COM x2 Open or Close direction PE Beams OR contact edge sensors with selectable functionality DIP SWITCH SETTINGS The DIP Switches located next...

Страница 13: ...stop the door After any adjustments are made test the operator 1 Open and close the door with the TEST BUTTONS ensuring that the door is stopping at the proper open and close limit positions 2 Place a...

Страница 14: ...r for vehicle or forklift mounting Security 2 0 Part No E945G Description 3 channel keyring transmitter Security 2 0 Part No E960G Description 4 channel keyring transmitter Security 2 0 Security Part...

Страница 15: ...as an open close and stop 1 Press and release the LEARN button operator will beep and green XMITTER LED will light NOTE The operator will time out of programming mode after 30 seconds 2 Press the remo...

Страница 16: ...his automatically sets the force When limits are set properly the operator will automatically exit limit setting mode ADJUST THE LIMITS if needed If the limits have already been set the operator will...

Страница 17: ...lose at OPEN limit INTERRUPT 2 Terminals This input is used for photoelectric sensors and external interrupt loop detector when loop is on the outside of the door Holds open door at open limit Stops a...

Страница 18: ...f sight Bypasses any prewarning delay ACCESSORY POWER 24 VDC MAX 500 MA 4 Terminals SWITCHED Switched ON when the door is in motion Turns off after a 5 second delay when the door stops The power will...

Страница 19: ...ure or out of balance conditions OPERATOR ALARM The operator alarm will beep 3 times with a command if the battery is low When the inherent force of the operator RPM current sensor detects the followi...

Страница 20: ...sual display connect an external buzzer or light low voltage Energizes if gate door is manually tampered with by being pushed off of close limit For an additional audible or visual display connect an...

Страница 21: ...es not reset alarm condition E Stop Input common 3 PB station 4 terminals total Stop command stops a moving door Hard stop maintained switch overrides Open and Close commands and resets alarm conditio...

Страница 22: ...ications extra care is required to prevent corrosion on rail and other metal components WARNING WARNING Always wear protective gloves and eye protection when changing the battery or working around the...

Страница 23: ...ect against fire and electrocution DISCONNECT power AC or solar and battery BEFORE installing or servicing operator For continued protection against fire Replace ONLY with fuse of same type and rating...

Страница 24: ...tivity TO RESET THE CODE HISTORY 1 Press and hold the STOP button for six seconds The display will show Er then CL alternately for six seconds 2 Release the STOP button The code history has now been r...

Страница 25: ...be set too tightly against a non resilient hard stop re adjust limit Operator may be at end of travel re adjust mounting NO 40 Battery overvoltage Too much voltage on the battery Check harness Make s...

Страница 26: ...canceling TTC 72 OPEN EYE EDGE triggered causing reversal or preventing opening 73 CLOSE EYE INTERRUPT triggered causing reversal preventing close or resetting TTC IF an obstruction occurred no actio...

Страница 27: ...charger or Solar power available BATT CHARGING OFF Not charging ON Three stage battery charging TIMER OFF The timer is disabled ON The timer is enabled MEDIUM BLINK 1 blink per second The timer is run...

Страница 28: ...active a Check all Open and Close inputs for a stuck on input b Check Stop button is not stuck on c Check Reset button d Charges batteries or replace batteries e Check all Entrapment Protection Device...

Страница 29: ...ion b Replace defective photoelectric sensor Retest that obstructing photoelectric sensor causes moving door to stop and may reverse direction Edge Sensor does not stop or reverse door a Incorrect edg...

Страница 30: ...setting incorrect b Interrupt loop detector c Defective Expansion board a Check that Anti Tail setting is ON b Check operation of Interrupt Loop detector c Replace defective Expansion board AUX Relay...

Страница 31: ...e Recti er EXPANSION BOARD Black Purple Brown Blue Gray Orange Orange Red Black Red CONTROL BOARD Piezo Alarm APS Encoder 1 2 HP 24 Vdc Motor ID Resistor White White Black Red Black Blue Red Reset But...

Страница 32: ...ights and remedies as a consumer charge you a fee to repair replace and or return the Operator to you This Chamberlain Limited Warranty does not cover any failure of or defect in the Operator due to 1...

Отзывы: