27
CONTROL BOARD LEDS
OPERATOR ALARM CHART
STATUS LEDS
INPUT LEDS
INPUT LEDS
OPEN, CLOSE, &
STOP INPUT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
FIRE DEPT INPUT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
EXIT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
SHADOW
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
CLOSE EYES/
INTERRUPT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
CLOSE EDGE
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
OPEN EYES/EDGE
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
LOCK
OFF
Maglock relay inactive
ON
Maglock relay active
STATUS LEDS
INPUT
POWER
OFF
OFF state
ON
AC charger or Solar power available
BATT
CHARGING
OFF
Not charging
ON
Three stage battery charging
TIMER
OFF
The timer is disabled
ON
The timer is enabled
MEDIUM BLINK (1 blink
per second)
The timer is running
FAST BLINK (2 blinks
per second)
The timer is paused
FASTEST BLINK (8
blinks per second)
The timer is canceled
DOOR
MOVING
OFF
The door is stopped
ON
The door is opening or closing
MEDIUM BLINK (1 blink
per second)
One force event
FASTEST BLINK (8
blinks per second)
Two force events
BATT LOW
OFF
No battery error
ON
Battery low
BLINK (1 blink per
second)
Battery critically low
ACC PWR
OVLD
OFF
OFF state
ON
Accessory overload protector opened
ALARM CHART
1 beep every 3 seconds
during door operation
Operator is operating from battery power. AC power
not connected
3 beeps every 3 seconds
during door operation
Operator is operating from LOW battery power. AC
power not connected.
2 beeps every minute
(constant)
Operator has encountered a double force based
obstruction.
TROUBLESHOOTING