CONNECTING EXTERNAL CONTROL DEVICES
EXIT
(2 Terminals)
This input is a soft open command (maintained switch does not
override external safeties and does not reset alarm condition). Used
for exit probe, telephone entry, external exit loop detector, or any
device that would command the door to open.
• Opens a closing door and holds open an open door, if
maintained, pauses Timer-to-Close at OPEN limit.
SHADOW
(2 Terminals)
This input is used for external shadow loop detector when loop is
positioned under the swing of the door.
• Holds open door at open limit
• Only active when the door is at the OPEN limit, disregarded at
all other times
• Pauses Timer-to-Close at OPEN limit
INTERRUPT
(2 Terminals)
This input is used for photoelectric sensors and external interrupt
loop detector when loop is on the outside of the door.
• Holds open door at open limit
• Stops and reverses a closing door to open limit
• Pauses Timer-to-Close at OPEN limit, activates quick close and
anti-tailgate features when enabled on the expansion board
CONNECTING ACCESS CONTROL ACCESSORIES
Access control devices can either be wired internally to the operator or via the external terminal block.
ACCESSORY WIRING
EXTERNAL CONNECTION
External terminals are provided for installations where 3rd party devices
can be connected without the need to gain entry to the operator enclosure.
Terminals are located on the rear of the operator, near the Reset Button.
DIAGNOSTICS
Normally Open
Access Contr
ol
Input
INTERNAL CONNECTION
The diagram below shows where to connect access control
devices such as card readers, keypads or key switches etc.
Normally Open
Access Control
Input