22
MAINTENANCE CHART
Disconnect all power (AC, battery) to the operator before servicing. The operator's AC Power switch ONLY turns off AC power to the
control board and DOES NOT turn off battery power. ALWAYS disconnect the batteries via the J15 plug to service the operator (refer
page 10).
BATTERY MAINTENANCE
Batteries will degrade over time depending on temperature and usage. The operator alarm will beep 3 times with a command if the battery
is low. Batteries do not perform well in extremely cold temperatures. For best performance, the batteries should be replaced every 3 years.
Use only Grifco replacement batteries. The operator comes with two 7AH batteries. The batteries contain lead and need to be disposed of
properly. If batteries are leaking, safely remove them and dispose of them properly. See page 9 for instructions.
DESCRIPTION
TASK
CHECK AT LEAST ONCE EVERY
MONTH
6 MONTHS
3 YEARS
Entrapment Protection
Devices
Check and test for proper operation
X
Manual Disconnect
Check and test for proper operation
X
Door
Make sure the door operates smoothly without the operator
X
Door Track
Make sure the door track runs smoothly
X
Accessories
Check all for proper operation
X
Operator Rail
Inspect and maintain the rail to ensure there is no corrosion
X
Electrical
Inspect all wire connections and circuit boards for visible
wear or damage
X
Operator
Inspect for wear or damage
X
Chain
Check tension and lubricate if needed
X
Batteries
Inspect the batteries and test the operator works without
mains connected
Test
Replace
In coastal applications, extra care is required to prevent corrosion on rail and other metal components.
WARNING
WARNING
Always wear protective gloves and eye protection when changing the battery or working around the battery compartment.
To reduce the risk of SEVERE INJURY or DEATH: READ AND
FOLLOW ALL INSTRUCTIONS.
• ALL maintenance MUST be performed by a Grifco professional.
• ANY maintenance to the operator or in the area near the
operator MUST NOT be performed until disconnecting the
electrical power
(AC or solar and battery) and locking-out the power via the
operator power switch. Upon completion of maintenance the
area MUST be cleared and secured, at that time the operator may
be returned to service.
• NEVER let children operate or play with door controls. Keep the
transmitter away from children.
• ALWAYS keep people and objects away from the door. NO ONE
SHOULD CROSS THE PATH OF THE MOVING DOOR.
• The entrance is for vehicles ONLY. Pedestrians MUST use
separate entrance.
• Test the door operator monthly. The door MUST reverse on
contact with a rigid object or reverse when an object activates
the non-contact sensors. After adjusting the force or the limit of
travel, retest the door operator. Failure to adjust and retest the
door operator properly can increase the risk of INJURY or
DEATH.
• Use the manual disconnect release ONLY when the gate/door is
not moving.
• KEEP DOOR PROPERLY MAINTAINED. Read the owner’s
manual. Have a qualified service person make repairs to door
hardware.
• Activate gate/door ONLY when it can be seen clearly, is properly
adjusted and there are no obstructions to gate/door travel.
• To reduce the risk of FIRE or INJURY to persons use ONLY
Grifco replacement batteries.
• Dispose of used batteries properly
• SAVE THESE INSTRUCTIONS.
MAINTENANCE