background image

AUTOMATION FOR SLIDING GATES

BK

INSTALLATION MANUAL

BK 800 - 1200 - 1800 - 2200

BKE 1200 - 1800 - 2200

Содержание BK 1200

Страница 1: ...AUTOMATION FOR SLIDING GATES BK INSTALLATION MANUAL BK 800 1200 1800 2200 BKE 1200 1800 2200 ...

Страница 2: ...sories are CAME originals this is a guarantee that also makes the system easy to set up and upkeep 4 Description 2 1 Destination 1 Legend This symbol indicates sections to be read with particular care This symbol indicates sections concernig safety This symbol indicates notes to communicate to users The following standard were complied with for this product EN 12978 UNI EN 954 1 CEI EN 60335 1 UNI...

Страница 3: ...IES 1 R001 Cylinder lock with DIN keys 2 BSF Braking device 3 BRC Cable winding device 4 B4353 Chain transmission device 5 CCT Simple 1 2 chain 6 CGIU 1 2 chain joint 7 CGZ Galvanized steel 22 x 22 module 4 rack 8 CGZS Galvanized steel 30 x 8 module 4 rack with fastening screws holes and supports 9 CGZ6 30 x 30 module M6 galvanised rack made of laminated steel for BK2200 and BKE2200 automated unit...

Страница 4: ...onnel must carry out the installation in full compliance with the applicable law 5 Installation 5 2 Tools and materials Make sure you have all the tools and materials handy to carry out the installation in total safety according to the laws in for ce Below is a drawing of the tools you will need to install the operator N B An evaluation of the size of the cables with lengths other than the data in...

Страница 5: ...clamps downwards Construct a cement foundation that is large enough to accomodate the gear motor it is a good idea to protrude 50 mm from the ground When pouring the foundation embed the gear motor anchor plate and the relative clamps in the cement The anchor bolts should be embedded in the concrete in the positions indicated the drive unit is then attached to this bots The anchor plate must be pe...

Страница 6: ...ible by the paten ted built in regulation system which consists of slots for horizontal adjustment threaded steel feet for vertical adjustment and levelling plates and bolts for anchorage to the base 5 5 Unit installation 5 6 Attaching the rack limit Attach the rack to the gate as described below Release the gearmotor parag 5 8 position the rack on the pinion of the gearmotor and slide the gate ma...

Страница 7: ...dicated To re lock the reduction gear turn key B in the direction indicated until it will move no further without forcing it the three sided pin will settle into place at the first movement 5 7 Attaching the switch tabs BK series Position the limit switch tabs whose positions determine the limits of gate travel on the rack Note do not allow the gate to strike the mechanical stops in the open or cl...

Страница 8: ... the 24V accessories must not exceed 20W The operating time interval is fixed at 150 seconds The photocells can be connected and set to re open during the closing phase re open during the opening phase partial stop total stop and obstacle sensing when motor is not running Note if a normally closed safety contact 2 C1 2 CX o 1 2 is opened this is indicated by the flashing LED ref point 9 main compo...

Страница 9: ... Connection for gear motor limit switch or encoder RED Invert the phases of the gear motor U V On the BK series invert wires FA FC On the BKE series invert the wires of the shielded cable BLACK Connection for encoder BKE series ZBKE ZBK Condenser Output for 230V a c motor con nection COM NC NO NO NC COM ORANGE WHITE RED ROSSO NERO Connection for encoder BKE series ZBKE ZBK Connection for the limit...

Страница 10: ...ed Courtesy lamp Contact output 230V 60 V max Auxiliary connection for suitably positioned external lamp to increase lighting of the steering area It remain lit for a fixed time of 5 minutes and 30 seconds DIP 16 ON DIP 17 OFF not included in the BK800 version Phase lamp Contact output 230V 60W max Auxiliary connection for a suitably positioned external lamp to increase lighting of the steering ar...

Страница 11: ...rds If in motion the gate leaf stops and automatic closing is consequently triggered DIP 8 OFF DIP 9 ON N C contact for re closing during opening phase Input for safety devices such as photocells sensiti ve safety edges and other devices compliant with EN 12978 standards When gate is opening if the contact is opened it triggers an inversion of the direction until gate is fully closed DIP 8 OFF DIP...

Страница 12: ... stand by time in the opening phase a k a pause time When the time elapses the gate automatically closes The pause time can be adjusted from 1 second to 150 seconds PAR OP Trimmer Partial opening Adjusts the gates opening time By pressing the partial opening button on 2 3P the gate will open for a pre set time of between 1 and 14 seconds With this function the automatic closing time will very as f...

Страница 13: ...nversion of movement direction until the gate is fully closed insert safety device into terminal 2 CX 8 OFF 9 ON Partial stop The gate stops completely when moving consequently triggering the automatic closing insert the safety device into terminal 2 CX if the devices on 2 CX are not used set dip switch 8 to the ON position 10 OFF Total stop This function stops the gate and consequently excludes a...

Страница 14: ...as long as the button is kept pressed N B By pressing the OPEN button during this procedure the led indicator does not turn on invert the phases of the motor U V and of the Encoder see para 6 3 electrical connections of the motor and encoder p 9 4 Re set DIP switch 15 to the OFF position 5 When the programming proce dure is finished open the door pa nel and block the gear motor with key B by turni...

Страница 15: ...ion dip switch 11 to the ON position to place it into a slave state N B Make sure that the radio frequency board is inserted only into the Master board A B 8 Connection of two coupled gear motors with single control A 4 Wire the electrical connections between the terminal boards as shown in the figure Note make sure that the automatic closing is trig gered by the master and deactivated in the slav...

Страница 16: ... on the command board paragraph 9 3 Radio board AF Motherboard TOP TAM 2 The AF board must ALWAYS be inserted into the coupling ref point 5 page 8 when the power is off because the motherboard only recognises it when it is powered Input for the remote control s antenna For opening and closing of the gate leaf using the remote control Con nect the RG58 cable to the terminal of the antenna with AF r...

Страница 17: ...A TFM T132 T134 T138 T152 T154 T158 CAME TOP SERIES 17 All the data and information contained herein is considered subject to change at any time and at our discretion ENGLISH set the code to dip switch C and channel to D P1 CH1 and P2 CH2 default setting set code only P1 CH1 P2 CH2 P3 CH3 P4 CH4 see instructions on pack see instruction sheet inside the pack see instruction sheet inside the pack ...

Страница 18: ... 4 disinserire jumper J 0 0 0 0 TOP T262M T302M FIG A FIG B P1 CH1 P2 CH2 P1 CH1 P2 CH3 P1 CH3 P2 CH2 P1 CH1 P2 CH4 P1 CH3 P2 CH4 TOP QUARTZ SERIES Press P1 or P2 in sequence in order to register the code at the tenth pulse a double beep will confirm that registration has occurred The first encoding operation must be carried out whilst keeping the jumpers positioned for channels 1 and 2 as per fig...

Страница 19: ...and at our discretion ENGLISH TCH 4024 TCH 4048 AT01 AT02 AT04 CAME 0 0 0 0 T264M T304M 0 0 0 0 0 0 T2622M T3022M P1 CH1 P2 CH2 P3 CH3 P4 CH4 1 Code P1 CH1 P2 CH2 2 Code P3 CH1 P4 CH2 ATOMO SERIES TOUCH SERIES see instruction sheet inside the pack of AF43SR circuit card see instructions on pack ...

Страница 20: ... Memorizing the code on the command board CH1 Channel for direct commands to a function of the ratiomotor control unit open only open clo se invert direction commands or the open stop close stop command depending on dip switch 2 3 settings 1 Keep the CH1 key pressed on the base card ref point 11 page 12 the signal LED will flash CH1 T1 3 Repeat the procedure of parts 1 and 2 with the CH2 key assoc...

Страница 21: ...ecycled by disposing of in specific re cyclable material collection bins and disposal in authorized centres Other components electrical boards remote control batteries etc however may contain polluting substances They should therefore be removed and given to qualified service companies for proper disposal Prior to disposal it is always advisable to check specific regulations in force in the place ...

Страница 22: ...Cod 119BS04 ver 4 0 01 06 CAME CANCELLI AUTOMATICI ...

Отзывы: