USER 1 - 24V DG
24V ELECTRONIC CONTROL UNIT FOR SLIDING GATES AND BARRIERS
67411535
International registered trademark n. 2.777.971
Страница 1: ...USER 1 24V DG 24V ELECTRONIC CONTROL UNIT FOR SLIDING GATES AND BARRIERS 67411535 International registered trademark n 2 777 971 ...
Страница 2: ... external controls and devices serving as required protection against entrapment shall be provided with the operator when such controls are shipped with the operator Instructions regarding intended installation of the gate operator shall be supplied as part of the installation instructions or as a separate document The following instructions or the equivalent shall be supplied where applicable a I...
Страница 3: ...by building structures natural landscaping or similar obstruction A wireless contact sensor shall function under the intended end use conditions 6 One or more contact sensors shall be located on the inside and outside leading edge of a swing gate Additionally if the bottom edge of a swing gate is greater than 6 inches 152 mm above the ground at any point in its arc of travel one or more contact se...
Страница 4: ...6 M Max 200W CN7 S 1 2 3 28V Battery charger Positive battery Neg t e b t e y h g r a iv a t r c ar e NOTE When using magnetic limit switches consider the respective inputs as N O LIMIT SWITCH CN2 Limit switch Cl 1 Yellow 24V Red Common White Limit switch Op 1 Green 1 WARNING The control unit is designed with the automatic detection of not used N C inputs photocells Stop and Limit switch except th...
Страница 5: ...ENT 16 JOLLY PROGRAMMER PARAMETER SETTING 17 START STOP PEDESTRIAN START ANTENNA PHOTOCELL CONNECTIONS 19 LIMIT SWITCH SENSOR BARRIERS 20 ALARM DESCRIPTION 20 POWER SUPPLY MOTOR CONNECTION EDGE BUZZER AND EXTERNAL RECEIVER 21 MASTER SLAVE FUNCTION 22 BATTERY CONNECTION 22 TROUBLE SHOOTING 23 WARNING MAINTENANCE AND WARRANTY 23 USER 1 24V DG INDEX International registered trademark n 2 777 971 5 67...
Страница 6: ...connector CNP Programming connector OK Programming button DOWN Programming button UP Programming button RD1 Motors piloting Mosfet RD3 Motors piloting Mosfet R1 Motors command relay R2 Motors command relay PR1 Rectifier jumper F1 Fuse 6 3 AT USER 1 24V DG CN8 F1 CN1 CNA CN3 CN5 CNP CN6 RL2 RL1 CN2 CN4 CN7 UP DOWN OK RD3 RD1 PR1 DISPLAY 1 2 3 4 5 6 7 8 9 10 11 12 13 1 6 International registered tra...
Страница 7: ...s It is of very small size and the big news is the LCD display on board that let you view and set in a simple and complete way all functions of the control unit USER 1 24V DG 24 V 30 mA 200W 24V 250mA 24V FL 15W max 20 C 50 C F1 6 3 AT Automatic S by Step1 S By Step2 Sec Dead man 2Butt In selflearning in programming phase Adjustable from to 4 min Adjustable Opening and Closing Adjustable Opening a...
Страница 8: ...o confirm and return to main menu Skip this step if a TX has already been stored UP DOWN ALL OTHER PARAMETERS HAVE DEFAULT SETTINGS WHICH ARE USEFUL FOR THE 90 OF THE APPLICATIONS BUT CAN BE HOWEVER SET THROUGH THE SPECIAL MENU FOR ENTERING INTO THE SPECIALMENU PRESS THE UPAND DOWN BUTTONSAT THE SAME TIME FOR 5 S OK UP DOWN PROGRAMMING BUTTONS QUICK START OK Press the button of the TX to be stored...
Страница 9: ... control board to the power supply Fig 6 3 Select on the on board display or JOLLY programmer the type of motor that you are using as indicated in the dispaly administration 4 Set the motor torque the working speed the deceleration and acceleration space and the slowdown speed If necessary also set the working logic and the other parameters 5 Select PROG on the display press OK and than one of the...
Страница 10: ...ating the related command on the display the item SET lights up the input will be working If SET is always on check the wirings The contact must be N C If activating the related command on the display the item SET lights up the input will be working If SET is always on make sure that the contact is a N C one The contact must be N C If activating the related command on the display the item SET ligh...
Страница 11: ... l 3 U u l 4 U u l 5 U Verg L 3m Verg L 4m Verg L 5m Exp output Transmitter Pedestrian Start Delete TX Delete single transmitter Motor type Sliding Hydraulic barrier Motor and limit switch inversion Synchronized right motor Synchronized left motor Working logics Automatic Step by step type 1 Step by step type 2 Two buttons Safety Dead man Time of pause Disabled Setting from 1s to 4min Start in pau...
Страница 12: ... opening Deceleration ramp in closing Pre flashing Pre flashing disabled Pre flashing active only before closing Preflashing duration Flash output adjustment Flashing lamp Control lamp Always ON Acceleration ramp Acceleration ramp Courtesy light Courtesy light disabled Courtesy light setting from 1s to 4min Pedestrian opening Adjusts the space of pedestrian opening Pedestrian Pause Pause in pedest...
Страница 13: ...ng 24Vaux output power supplied only during opening 24Vaux output power supplied only during cloisng 24Vaux output power supplied only during pause 24Vaux output for connection of photocell TX to autotest Phototest economy Output for Self test ON only during the operation of the motors Position recovery Regulates the recovery of the motor inertia Limit switch inversion Disabled Adjusts the space o...
Страница 14: ...ue Photocell management exclusion Excludes the operation of the photocell during closing for the set percentage For applications with two motors in master slave you can set the control unit as slave For applications with two motors in master slave it allows to set the control unit as master Master slave management Exit special menu Enter password Select END and press OK to exit the special menu Th...
Страница 15: ...e to memorize up to max 30 codes buttons You can store max 2 of the available 4 functions If the control unit receives a code which was already associated to another function it will be updated with the new function DELETE TRANSMITTERS FROM THE RECEIVER With modules different from RF UNI it will be possible to delete only the entire memory of the receiver Proceed as follows select from the menu DE...
Страница 16: ...omatic closing it is necessary to set a pause time otherwise all the logic will be semi automatic NOTE2 It is possible to choose whether to accept or not the start in pause selecting in the MENU the item ST PS and choosing ON or OFF By default the parameter is OFF With a new control unit all menus can be displayed and set and the password will be disabled Selecting one of the Menus and keeping UP ...
Страница 17: ...ed adjustment Sp Decel C1 Off 100 motor 1 slowdown space in closing adjusmtent Torque op M1 10 100 max motors current SoftStart 0 100 motor 2 slowdown space in closing adjustment Torque cl M1 10 100 max motors current Cycle Secur auto deadman step1 step2 two buttons Pause time 0 240 s pausing time in seconds 0s halfautomatic logic Learning Times learning On Off Cycles 0 Number of executed cycles P...
Страница 18: ...ause the immediate closure of the gate Timer OFF Ped Foto2 Allows the timer activation on the Foto2 or pedestrian input Mot inv ON OFF Allows to changes at the same time the limit switch and the direction of motor rotation without disconnecting the cables Rev Mot 0 100 Activates an inversion at the end of closing P Ped start Off 0 240 sec Differenciates the pedestrian pause from the total one Star...
Страница 19: ...tart ped Stop Common Photocell 1 CN1 1 2 3 4 5 6 7 8 Photocell 2 RX1 RX2 TX1 TX2 CN1 9 10 11 12 13 Common 24V FL OPTIONS ON FOTO1 and FOTO2 adjustable on on board display or with JOLLYterminal FOTO CLOSE activation los if occupied reverses the movement in closing during pause it prevent the closing Activation repeat pause rP PA If occupied during pause it recharges the timer of pause In closing it...
Страница 20: ...TIONS Flashings Number 9 2 3 6 4 Flashings Number 5 7 6 4 fast Kind of alarm Motors fault Photocell in closing Photocell in opening Opening impact Safety edge Kind of alarm Stop Max Reached cycles Closing impact Limit switch error Battery voltage fault F BAT If network is not present Motors current fault 24V Power supply fault 24Vaux output voltage Power supply fault FAUL FT 24 FT AU FT LI Sure th...
Страница 21: ...In case of imbalance of the device a special alarm will show on the on board dispaly or on the JOLLYprogrammer SECURITY EDGE AND WARNING LAMP OR BUZZER EXTERNAL RECEIVER Example Connection of a radio receiver For the connection of the receiver refer to the relative instructions manual Common Common Start ped International registered trademark n 2 777 971 Flashing Lamp 24V 15W Warning lamp or Buzze...
Страница 22: ...ugh the special clamp Code SEA23001220 3 Now set the control unit which has to manage the commands and motor 1 photocell keyswitch STOP safety edge etc as MASTER and the other one which will move motor 2 as SLAVE 4 Follow up the selflearning of the times of the MASTER control unit Note 1 The master and slave settings on the control unit are present in the special menu selecting ASL Note 2 All thes...
Страница 23: ...mplains and or claims must be notified to SEAwithin 7 business days after receiving the products Claims and complains must be supported by original documents Customer must contact the factory for instructions and authorization Merchandise returned for credit must be current uninstalled and unused and returned in its original packaging Freight must be pre paid on all authorized returns REPAIRS Repa...