![Green Technik CIP 1300 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/green-technik/cip-1300/cip-1300_operation-and-maintenance-handbook_2261249031.webp)
CIP 1300 – Use and Maintenance Manual
30
V
C
Chapter
11
ORDINARY MAINTENANCE
CAUTION:
Danger of injury
To carry out the operations described above it is obligatory to
wear protective gloves, glasses or a protective visor and safety
shoes.
CAUTION:
Before any maintenance or adjustment operation, switch off the
engine and remove the key from the control panel.
11.15 Checking the tension /
Replacement of the
transmission belts
(motorised version)
Switch off the engine and make sure
the flywheel has stopped completely.
Undo the screws of the protective
casing
(C)
and remove it
.
Check the tension
(T)
of the belts by
pressing with your hand. If the belt
lowers by more than 15 mm the
tension must be adjusted
.
Check the efficiency of the transmission
belts and if they are worn replace them,
proceeding as follows.
slacken the 3 screws of the engine
support
(R)
slacken the counternut and unscrew
the adjustment screw
(V)
replace the belts
Fasten the screw
(V)
and check the
tension of the belts. Fasten the
counternut and the screws
(R)
Put back the casing
(C)
and fasten it
with the screws.
V
R
CIP 1300 H24
V
CIP 1300 Y11 – CIP 1300 L17