ORDINARY MAINTENANCE
CAUTION:
Danger of injury
Before carrying out any maintenance or adjustment work, switch
off the engine and remove the key from the control panel and, with
the PTO machine, disconnect the cardan shaft
To carry out the operations described above it is obligatory to
wear protective gloves, glasses or a protective visor and safety
shoes.
WARNING:
Never rotate the flywheel by hand. Before putting your hands
near the blades or the counter-blade make sure the flywheel
has come to a complete standstill.
11.4 Replacing the blades
Switch off the engine and make sure
the flywheel has come to a complete
standstill.
Undo the four M8 screws of the
inspection panel
(A)
and remove it.
Immobilise the disk (
D)
as described in
paragraph
11.2
.
Undo and extract the fixing screws of
the blade
(V).
Check the blade
(C)
: if the opposite
cutting edge is sharp you only have to
invert the position and fasten it. If it is
not, replace it with a new or sharpened
blade.
Repeat the procedure for the
remaining blades.
N.B.: Take every precaution when
rotating the flywheel.
Before disassembling the blades
make sure the flywheel is
completely still.
Insert the immobilising wedge.
Proceed with adjusting the blades and
the counter-blade as described in the
previous paragraph..
Check that all the screws are properly
tightened.
At the end of the operation, remove the
wedge, put back the two inspection
panels and fasten them with the
screws.
V
C
A
D