48
M_LS1000 XP_EN_C
Operating instructions for the machine
Control parameters
Order
Code
Functions
Range of
values
Initial setup
*
Notes
1
F0
Constant temperature
5 ─› 40
25
Constant
temperature
control
2
F1
Temperature
difference values
-15 ─› +5
-2
Intelligent control
3
F2
Cooling hysteresis
0.2 ─› 3.0
0.8
Constant
temperature
control
4
F3
Control mode
0 ─› 1
1
0: Constant
temperature
control
1: Intelligent
control
5
F4
Alarm: Maximum
water temperature
exceeded
1 ─› 20
10
6
F5
Alarm: Water
temperature below
the minimum
1 ─› 20
15
7
F6
Alarm: Maximum
ambient temperature
exceeded
40 ─› 50
45
8
F7
Password
00 ─› 99
8
9
F8
Permissible water
temperature:
Maximum
F9 ─› 40
30
Intelligent control
10
F9
Permissible water
temperature:
Minimum
5 ─› F8
20
Intelligent control