30
M_LS1000 XP_EN_C
Recommendations for installation
7. Connecting/disconnecting the water chiller
Connecting the water chiller
1. Fill the tank with demineralised water until the water level reaches the green area (NORMAL) on the
gauge. To avoid any contamination, it is recommended that a biocide be added to the demineralised
water.
In order to protect the chiller pump, it is strictly prohibited to operate it without demineralised
water in the tank. In order to ensure optimal performance, it is advisable to keep the water
level in the tank within the green area (NORMAL) on the gauge.
Demineralised water must be used in the tank in order to prevent damage to the metal material.
1.
Water tank intake
2.
Water level gauge
3.
Cooling water outlet (cooled water)
4.
Cooling water intake (water to be cooled)
2. Connect the black hose to the water outlet on the chiller.
3. Connect the blue hose to the water intake on the chiller.
4. Connect the black hose to the intake on the machine.
5. Connect the blue hose to the outlet on the machine.
6. Check that the drain plug is properly tightened.
Check that the hoses are properly connected. Make sure there are no leaks.
1
2
3
4