32
M_LS1000 XP_EN_C
Recommendations for installation
8. Electrical installation
The connection to the single phase power supply is made with a standard, 3 pin plug with
grounding. Grounding must be done according to the regulations in effect to ensure the
safety of the personnel.
Check that the electrical installation meets the requirements of the "Input power" label located close to the
machine's power supply socket.
40W-60W-80W:
100W-150W:
To avoid interference problems due to the external environment, observe the following:
•
Use the link cables supplied. They comply with EMC radio-frequency interference emission standards and
provide protection from external electrical interference (compliant with EMC immunity and susceptibility
standards).
•
Bring the items of equipment to be linked as close together as possible to reduce the length of cable to be
used.
•
Separate the power cable from the link cable and make sure the power and link cables do not run through
the same cable tray.
•
Connect the machine direct to a mains power line and avoid connecting more than one device to that line
(by plugging several devices into the same mains socket or into a multi-way adapter).
•
Do not allow inductive or capacitive devices to be connected to the same mains power line as the machine
(motors, solenoid valves, chargers, etc.).
•
Avoid the installation of manual or automatic switching systems on the same mains power line as the
machine (relays, timers, programmers, automatic circuit-breakers, automatic switches, etc.).
•
Check that devices in the vicinity of the machine meet the standards for electromagnetic interference.
Read the technical data sheet for each device. If they are non-compliant, move them as far away from the
machine as possible.
•
Use the Gravograph accessories.
Always switch the machine off before connecting or disconnecting a cable or optional
accessory.