46
M_LS1000 XP_EN_C
Operating instructions for the machine
3.
Control panel: Water chiller (only for 100W/150W laser sources)
RST:
"Check" key
SET:
"Function adjustment" key.
Red light D1
Status
Meaning
indicator light on
The controller is operating in intelligent control mode.
Indicator light not
illuminated
The controller is operating in constant temperature control mode.
The light flashes.
The controller is operating in setting adjustment mode or is displaying ambient temperature values
in the room.
Red light D2
Status
Meaning
indicator light on
The chiller is operating in cooling mode.
Indicator light not
illuminated
The chiller is operating in isolation mode.
The light flashes.
The chiller is operating in energy saving mode.
The arrows enable the operator to adjust the controller, the display mode and the selection and adjustment
of a setting.
In any mode, press the down arrow and the display shows the ambient temperature in the room.
Reset
Before starting the machine, press and hold down both arrows until the controller displays "rE".
The controller returns to normal operation, 6 second(s) after the keys are released.
All the factory settings for the controller are then restored.