12 - 45
12.16
CONTINUITY DIAGRAMS
Models 990014, 990015, 990017
OFF
M
G
S2
B
S1
A
M
G
S2
B
S1
A
START
M
G
S2
B
S1
A
Key Switch
(03602300)
Relay
(046216)
87
87A
86
85
30
NOT ENERGIZED
87
87A
86
85
30
ENERGIZED
3
9
4
7
1
DISENGAGED
(down position)
3
9
4
7
1
ENGAGED
(up position)
PTO Switch
(01545600)
Seat Switch
(03654200)
1
OPERATOR
OFF SEAT
2
1
OPERATOR
ON SEAT
2
Neutral Switch
(050480)
RUN
1
2
ENGAGED
(button out)
1
2
NEUTRAL
(button in)
Brake Switch
(03657100)
B U T T O N I N
BUTTON OUT
Solenoid (990017 Models Only)
(03057700)
NOT ENERGIZED
ENERGIZED
The diagrams below show the various states of connection for electrical components.
The solid lines on switches show continuity.
NOTE: All switches are viewed from the rear.