Advanced Display Module (ADM) Operation
Home
Home
Home
System
System
System Off
Off
Off
This is the home screen when the system is off.
This screen displays actual temperatures, actual
pressures at the luid manifold, and number of cycles.
Home
Home
Home
System
System
System Active
Active
Active
When the system is active, the home screen displays
actual temperature for heat zones, actual pressures
at the luid manifold, the number of cycles, along with
all associated control soft keys.
Use this screen to turn on heat zones, start the
proportioner, stop the proportioner, park the
component A pump, and clear cycles.
NOTE:
NOTE:
NOTE: Screen shown displays inlet sensor
temperatures and pressures. These will not be
shown on models without inlet sensors.
Home
Home
Home
System
System
System With
With
With Error
Error
Error
Active errors are shown in the status bar. The error
code, alarm bell, and description of the error will
scroll in the status bar.
1. Press
to acknowledge the error.
2. See
for corrective
action.
Targets
Targets
Targets
Use this screen to deine the setpoints for the
A Component Temperature, B Component
Temperature, heated hose temperature, and
pressure.
Maximum
Maximum
Maximum AAA and
and
and BBB temperature:
temperature:
temperature: 190°F (88°C)
Maximum
Maximum
Maximum heated
heated
heated hose
hose
hose temperature:
temperature:
temperature: the lesser of
10°F (5°C) above the highest A or B temperature
setpoint or 180°F (82°C).
Note
If the remote display module kit is used,
these setpoints can be modiied at the gun.
334945C
39
Содержание Reactor 2 Hydraulic
Страница 19: ...Notes Notes Notes Notes 334945C 19...
Страница 68: ...Dimensions Dimensions Dimensions Dimensions 68 334945C...
Страница 69: ...Notes Notes Notes Notes 334945C 69...