Connect
Connect
Connect Power
Power
Power
NOTE:
NOTE:
NOTE: All electrical wiring must be done by a
qualiied electrician and comply with all local codes
and regulations.
1. Turn main power switch (MP) OFF.
2. Open electrical enclosure door.
NOTE:
NOTE:
NOTE: Terminal jumpers are located inside the
electrical enclosure door if equipped.
3. Install supplied terminal jumpers in the positions
shown in image for the power source used (H-30
and H-XP2 models only).
4. Route power cable through strain relief (EC) in
electrical enclosure.
5. Connect incoming power wires as shown in
image. Gently pull on all connections to verify
they are properly secured.
6. Verify all items are connected properly as shown
in image then close electrical enclosure door.
ti26342a_17D775
Table
Table
Table 555 Power
Power
Power Cord
Cord
Cord Requirements
Requirements
Requirements
Model
Model
Model
Input
Input
Input Power
Power
Power
Cord
Cord
Cord Speciications*
Speciications*
Speciications*
AWG
AWG
AWG (mm^2)
(mm^2)
(mm^2)
200-240 VAC,
1 Phase
4 (21.2),
2 wire + ground
200-240 VAC,
3 Phase, DELTA
8 (8.4),
3 wire + ground
H-30, 10.2
kW
350-415 VAC,
3 Phase, WYE
8 (8.4),
4 wire + ground
200-240 VAC,
1 Phase
4 (21.2),
2 wire + ground
200-240 VAC,
3 Phase, DELTA
6 (13.3),
3 wire + ground
H-30, 15.3
kW
350-415 VAC,
3 Phase, WYE
8 (8.4),
4 wire + ground
200-240 VAC,
1 Phase
4 (21.2),
2 wire + ground
200-240 VAC,
3 Phase, DELTA
6 (13.3),
3 wire + ground
H-XP2,
15.3 kW
350-415 VAC,
3 Phase, WYE
8 (8.4),
4 wire + ground
200-240 VAC,
3 Phase, DELTA
6 (13.3),
3 wire + ground
H-40, 15.3
kW
350-415 VAC,
3 Phase, WYE
8 (8.4),
4 wire + ground
200-240 VAC,
3 Phase, DELTA
4 (21.2),
3 wire + ground
H-40, 20.4
kW
350-415 VAC,
3 Phase, WYE
6 (13.3),
4 wire + ground
200-240 VAC,
3 Phase, DELTA
4 (21.2),
3 wire + ground
H-50, 20.4
kW
350-415 VAC,
3 Phase, WYE
6 (13.3),
4 wire + ground
200-240 VAC,
3 Phase, DELTA
4 (21.2),
3 wire + ground
H-XP3,
20.4 kW
350-415 VAC,
3 Phase, WYE
6 (13.3),
4 wire + ground
*Values are for reference only. Refer to amperage
listed in Models table (see
) for given
system and compare against latest version of local
electrical code to select proper power cord size.
NOTE:
NOTE:
NOTE: 350 415 VAC systems are not designed to
operate from 480 VAC power source.
30
334945C