6. Turn off the air compressor, air dryer, and
breathing air.
7. Turn main power switch OFF.
To prevent electric shock do not remove any covers
or open the electrical enclosure door while the
power is ON.
8. Close all luid supply valves.
9. Set PRESSURE RELIEF/SPRAY valves to
SPRAY to seal out moisture from the drain line.
10. Engage gun piston safety lock then close luid
inlet valves A and B.
Fusion
Fusion
Fusion
Probler
Probler
Probler
Pressure
Pressure
Pressure Relief
Relief
Relief Procedure
Procedure
Procedure
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure
is manually relieved. To help prevent serious
injury from pressurized luid, such as skin injection,
splashing luid and moving parts, follow the
Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing
equipment.
The Fusion AP gun is shown.
1. Press
to stop the pumps.
2. Turn off all heat zones.
3. Relieve pressure in gun and perform gun
shutdown procedure. See gun manual.
4. Close gun luid inlet valves A and B.
5. Shut off feed pumps and agitator, if used.