Standby
Standby
Standby
If you stop spraying for a period of time, the unit will
enter standby by shutting down the electric motor
and hydraulic pump, to reduce equipment wear and
minimize heat buildup. The pump icon on the ADM
Home screen will lash when in standby.
NOTE:
NOTE:
NOTE: The A, B, and Hose heat zones will not shut
off during standby.
To restart, spray off target for two seconds. The
system will sense the pressure drop and the motor
will ramp up to full speed in a few seconds.
NOTE:
NOTE:
NOTE: This feature is disabled from the factory.
To activate or deactivate standby:
1. Enter setup mode by pressing
on the ADM.
2. Go to screen System 3 and select to
enter
the page for editing.
3. Select the Standby Idle Time drop down using
and the arrow keys. Select the desired delay
using
and the arrow keys. Press enter to
select the desired value.
4. Exit the page and return to run mode by pressing
, then
.
Shutdown
Shutdown
Shutdown
NOTICE
NOTICE
NOTICE
Proper system setup, startup, and shutdown
procedures are critical to electrical equipment
reliability. The following procedures ensure steady
voltage. Failure to follow these procedures will
cause voltage luctuations that can damage
electrical equipment and void the warranty.
1. Press
to stop the pumps.
2. Turn off all heat zones.
3. Relieve pressure. See
Pressure Relief Procedure, page 54
4. Press
to park the Component A and
Component B pumps. The park operation is
complete when green dot goes out. Verify the
park operation is complete before moving to next
step.
5. Press
to deactivate the system.
334945C
53
Содержание Reactor 2 Hydraulic
Страница 19: ...Notes Notes Notes Notes 334945C 19...
Страница 68: ...Dimensions Dimensions Dimensions Dimensions 68 334945C...
Страница 69: ...Notes Notes Notes Notes 334945C 69...