Error
Location
Type
Description
Cause
Solution
High ambient
temperature.
Ensure ambient
temperature is below
120°F(48°C) before using
the system.
Enclosure fan not
operating.
Ensure fan in electrical
enclosure is spinning. If it
is not, check fan wiring or
replace fan.
T4CT
TCM
High Temperature
TCM
Module fan not
operating.
If a TCM fan error (WMI0)
has occurred, fan inside
the module is not working
properly. Check TCM fan
for debris and clear with
forced air if necessary.
Bad RTD or bad
RTD placement
against heater.
Swap A and B heater output
cables and RTD cables and
see if issue follows. If so,
replace RTD.
T4DA
Heater A
High Temperature A
Flow too high
for temperature
setpoint, causing
temperature
overshoots when
gun is de-triggered.
Use a smaller mix chamber
that is rated for the unit in
use.
Bad RTD or bad
RTD placement
against heater.
Swap A and B heater output
cables and RTD cables and
see if issue follows. If so,
replace RTD.
T4DB
Heater B
High Temperature B
Flow too high
for temperature
setpoint, causing
temperature
overshoots when
gun is de-triggered.
Use a smaller mix chamber
that is rated for the unit in
use.
333024A
27
Содержание Reactor 2 E-30
Страница 69: ...Parts Parts Proportioners 333024A 69...
Страница 82: ...Parts Electrical Enclosure 82 333024A...
Страница 90: ...Electrical Schematics Available Circuit Breakers Part Amps 126128 20 126131 40 24L960 50 90 333024A...
Страница 91: ...Electrical Schematics 1 16U529 16V515 15D906 24U855 1 Locate near TCM 333024A 91...