Error
Location
Type
Description
Cause
Solution
Broken or loose
RTD cable or
connection.
Check all wiring and
connection to RTD.
T6DB
Heater B
Sensor Error B
Bad RTD.
Switch the RTD with
another and see if the error
message follows the RTD.
Replace RTD if the error
follows the RTD.
T6DH
Hose
Sensor Error Hose
Broken RTD cable
in hose or bad FTS.
Expose each hose RTD
connection to check
and retighten any loose
connector. Measure
hose RTD cable and
FTS continuity. Order
RTD Test kit 24N365 for
measurement.
Disconnect hose RTD and
use manual hose mode to
finish job until repair can be
completed.
Broken RTD cable
in hose or bad FTS.
Expose each hose RTD
connection to check
and retighten any loose
connector. Measure
hose RTD cable and
FTS continuity. Order
RTD Test kit 24N365 for
measurement.
Disconnect hose RTD and
use manual hose mode to
finish job until repair can be
completed.
T6DT
TCM
Sensor Error TCM
Broken Heater
RTD
If the error still occurs with
the hose FTS unplugged,
one of the heater RTDs
is bad. Unplug the A or
B RTD from the TCM. If
unplugging an RTD fixes
the T6DT error, replace the
RTD.
30
333024A