Problem
Cause
Solution
Loose wire.
Check.
See
Electrical Schematics, page 89
Fan blade obstructed.
Remove obstruction.
Cooling fans not working.
Defective fan.
Replace. See
Obstructed fluid hose or gun; fluid
hose ID too small.
Open, clear; use hose with larger
ID.
Worn piston valve or intake valve
in displacement pump.
See pump manual.
Pump output low.
Pressure setpoint too high.
Reduce setpoint and output will
increase.
Fluid leak in pump packing nut
area.
Worn throat seals.
Replace. See pump manual.
No pressure on one side.
Fluid leaking from heater inlet
rupture disk (372).
Check if heater and PRESSURE
RELIEF/SPRAY valve (SA or SB)
are plugged. Clear. Replace
rupture disk (372) with a new one;
do not replace with a pipe plug.