7. Perform
Pressure Relief Procedure, page 42
.
8. Remove the system frame from the floor and
L-brackets.
9. Remove two bolts and nuts and fold the electrical
enclosure backward.
10. Remove screws (21) and motor shroud (11).
Rest the motor shroud behind the motor without
straining the fan power cable.
Note
Examine bearing housing (103) and
connecting rod (105). If these parts need
replacing, first remove the pump (106),
see
.
11. Remove cover (60) and screws (21).
12. Remove cycle counter (121) from housing by
removing screw (122).
13. Disconnect pump inlet and outlet lines. Remove
screws (113), washers (115), and bearing
housing (103).
NOTICE
Do not drop gear cluster (104) when removing
drive housing (102). Gear cluster may stay
engaged in motor front end bell or drive
housing.
14. Remove screws (112, 119) and washers (114)
and pull drive housing (102) off motor (101).
Note
The A side drive housing includes cycle
counter switch (121). If replacing this
housing, remove screws (122) and
switch. Reinstall screws and switch on
new drive housing.
Figure 6
333024A
51
Содержание Reactor 2 E-30
Страница 69: ...Parts Parts Proportioners 333024A 69...
Страница 82: ...Parts Electrical Enclosure 82 333024A...
Страница 90: ...Electrical Schematics Available Circuit Breakers Part Amps 126128 20 126131 40 24L960 50 90 333024A...
Страница 91: ...Electrical Schematics 1 16U529 16V515 15D906 24U855 1 Locate near TCM 333024A 91...