Error
Location
Type
Description
Cause
Solution
Inlet sensors not
installed.
If inlet sensors are not
installed, inlet sensors
should be disabled on the
System Setup screen.
Loose/bad
connection.
Check to ensure inlet
sensor is properly installed
and all wires are properly
connected.
P6FB
MCM
Pressure Sensor
Error Inlet B
Bad sensor.
Check if the error follows
the inlet sensor. Disconnect
inlet sensor cables from
the MCM (connectors 8
and 9). Reverse A and B
connections and check if
the errors follows. If the
error follows the sensor,
replace the inlet sensor.
Pressure
difference between
A and B material
is greater than the
defined value.
Ensure material flow is
equally restricted on both
material lines.
Pressure
imbalance is
defined too low.
Ensure that the pressure
imbalance value, on the
System Setup screen, is at
an acceptable maximum
pressure to prevent
unnecessary alarms and
abort dispenses.
Out of material.
Fill tanks with material
Fluid leaking from
heater inlet rupture
disk.
Check if heater
and PRESSURE
RELIEF/SPRAY valve are
plugged. Clear. Replace
rupture disk. Do not replace
with a pipe plug.
P7AX
MCM
Pressure Imbalance
A High
Feed system
defective.
Check feed pump and
hoses for blockage. Check
that feed pumps have
correct air pressure.
333024A
23
Содержание Reactor 2 E-30
Страница 69: ...Parts Parts Proportioners 333024A 69...
Страница 82: ...Parts Electrical Enclosure 82 333024A...
Страница 90: ...Electrical Schematics Available Circuit Breakers Part Amps 126128 20 126131 40 24L960 50 90 333024A...
Страница 91: ...Electrical Schematics 1 16U529 16V515 15D906 24U855 1 Locate near TCM 333024A 91...