Replace Transformer
1. Perform
2. Remove four bolts (23) and shroud (10).
3. Remove lower dinrail cover (48).
4. Disconnect fan and transformer connections
from terminal blocks. Connections are on left
side labeled: V+, V-, 1, 2, 3, and 4.
5. Remove four nuts (27) holding metal transformer
cover (8) to frame. Carefully remove cover while
sliding wires through hole in cover.
6. Remove nuts (27) and transformer (17).
7. Install transformer (17) in reverse order.