Error
Location
Type
Description
Cause
Solution
L1AX
ADM
Low Chemical Level
A
Low material level. Refill material and update
drum level on ADM
Maintenance screen.
Alarm can be disabled on
the System Setup screen.
L1BX
ADM
Low Chemical Level
B
Low material level. Refill material and update
drum level on ADM
Maintenance screen.
Alarm can be disabled on
the System Setup screen.
MMUX
USB
Maintenance Due -
USB
USB logs have
reached a level
where data loss
will occur if logs are
not downloaded.
Insert a USB drive into the
ADM and download all logs.
Pressure
difference between
A and B material
is greater than the
defined value.
Ensure material flow is
equally restricted on both
material lines.
Pressure
imbalance is
defined too low.
Ensure that the pressure
imbalance value, on the
System Setup screen, is at
an acceptable maximum
pressure to prevent
unnecessary alarms and
abort dispenses.
Out of material.
Fill tanks with material
Fluid leaking from
heater inlet rupture
disk.
Check if heater
and PRESSURE
RELIEF/SPRAY valve are
plugged. Clear. Replace
rupture disk. Do not replace
with a pipe plug.
P0AX
MCM
Pressure Imbalance
A High
Feed system
defective.
Check feed pump and
hoses for blockage. Check
that feed pumps have
correct air pressure.
333024A
19
Содержание Reactor 2 E-30
Страница 69: ...Parts Parts Proportioners 333024A 69...
Страница 82: ...Parts Electrical Enclosure 82 333024A...
Страница 90: ...Electrical Schematics Available Circuit Breakers Part Amps 126128 20 126131 40 24L960 50 90 333024A...
Страница 91: ...Electrical Schematics 1 16U529 16V515 15D906 24U855 1 Locate near TCM 333024A 91...