Repair Circuit Breaker Module
1. See
Before Beginning Repair, page 46
2. Using an ohmmeter, check for continuity across
circuit breaker (top to bottom). If no continuity,
trip breaker, reset, and retest. If still no continuity,
replace breaker as follows:
a. Refer to
Electrical Schematics, page 89
, and
circuit breaker table.
b. Follow Shutdown instructions. See
.
c. Refer to circuit breaker identification table
and electrical diagrams in Reactor repair
manual.
d. Loosen two screws connecting wires and bus
bar to circuit breaker that will be replaced.
Disconnect wires.
e. Pull locking tab out 1/4 in. (6mm) and pull
circuit breaker away from the din rail. Install
new circuit breaker. Insert wires and tighten
down all screws.
Figure 8
Circuit Breakers
Circuit Breakers
Ref.
Size
Component
CB01
50 A
Heated Hose
CB02
20 A
Motor Control Module
(MCM)
CB03
40 A
ISO Heater
CB04
40 A
RES Heater
CB05
40 A
Hose Heat Transformer
54