Troubleshooting
32
3A6165J
P3DA
High Pressure
Outlet A
Pressure A exceeds user-defined
limit
Inspect for hardened material or
obstructions to flow.
Attempt to purge material at a
reduced flow rate.
Reduce operating pressure by
reducing flow rate and/or restriction
in the hose and valve.
Check pressure settings on setup
screen.
P3DB
High Pressure
Outlet B
Pressure B exceeds user-defined
limit
Inspect for hardened material or
obstructions to flow.
Attempt to purge material at a
reduced flow rate.
Reduce operating pressure by
reducing flow rate and/or restriction
in the hose and valve.
Check pressure settings on setup
screen.
P3DC
High Pressure
Deviation Outlet A
Pressure A exceeds user-defined
dispense pressure limit.
Inspect for hardened material or
obstructions to flow.
Attempt to purge material at a
reduced flow rate.
Reduce operating pressure by
reducing flow rate and/or restriction
in the hose and valve.
Check pressure settings on setup
screen.
P3DD
High Pressure
Deviation Outlet B
Pressure B exceeds user-defined
dispense pressure limit.
Inspect for hardened material or
obstructions to flow.
Attempt to purge material at a
reduced flow rate.
Reduce operating pressure by
reducing flow rate and/or restriction
in the hose and valve.
Check pressure settings on setup
screen.
P3FA
High Pressure Inlet
A
Supply pressure is too high
Reduce inlet supply pressure. Inlet
pressure should not exceed 67% of
outlet pressure.
Outlet operating pressure is too low
Increase outlet operating pressure.
Outlet pressure should be at least
1.5x inlet pressure.
Error Code
Code Description
Cause
Solution